[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC general system tamper



=CE=A4=CE=B7 =CE=94=CE=B5=CF=85=CF=84=CE=AD=CF=81=CE=B1, 25 =CE=9C=CE=B1=CF=
=81=CF=84=CE=AF=CE=BF=CF=85 2019 - 4:19:07 =CF=80.=CE=BC. UTC+2, =CE=BF =CF=
=87=CF=81=CE=AE=CF=83=CF=84=CE=B7=CF=82 mleuck =CE=AD=CE=B3=CF=81=CE=B1=CF=
=88=CE=B5:
> On Friday, March 22, 2019 at 1:27:49 PM UTC-5, spyros wrote:
> > The situation is the above. PC1616, PK5501, RF5132 and Envisalink4. I g=
et servive fault general system tamper. The tamper at RF5132 is ok, also i =
disable wireless zone supervisions and also disable rf jam detection but st=
ill get the error. Any idea? Thank you...
>=20
> What version is the RF5132?=20
>=20
> DSC came out with this on the v5.0 back in 2006
>=20
> DSC would like to inform you of a possible issue regarding the RF5132 ver=
sion
> 5.0 wireless receivers regarding the new case and wall tamper options.
> Several units have been shipped with the case and wall tamper options ena=
bled.
> If enabled, the control panel will display a General System Tamper troubl=
e.
> To disable the case and wall tamper options in the RF5132 version 5.0 wir=
eless
> receiver:
> =E2=80=A2 Enter [*][8][Installers Programming] to enter Installers Progra=
mming
> =E2=80=A2 Enter Section [804] to enter Wireless Receiver Programming
> =E2=80=A2 Enter Section [90] and turn ON Options [3] and [4] to disable t=
he tampers
> We apologize for any inconvenience this may cause.

Thank you my friend, i'll try this and i'll let you know!


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home