Re: Honeywell Vista 20P - Reprogramming to allow entry/exit delay for backdoor.
02 will make it a entry 2 ( be sure and set the amount of time your
want at * 36)
Exit time will be same for both...
RTS
On 8/10/2017 1:52 PM, crafow@xxxxxxxxx wrote:
> Can someone confirm or advise whether what I am thinking of doing will work for my Vista 20P Honeywell alarm system.
>
> Desired outcome: add a delayed entry/exit for a backdoor(leaving the front door on a delayed entry as well)
>
> Current configuration:
> Residential home currently programmed with 8 zones.
>
> Front door is on zone 2 by itself, currently programmed as type 01 zone with delayed entry/exit.
>
> Backdoor and kitchen & Porch windows are on Zone 3 (which currently does not allow for a delayed entry of the backdoor)
>
>
> Based on the Youtube videos I've watched and reading of various manuals/sites. I am thinking that if I merely reprogram Zone 3 to a type 02 or 03 zone this will allow for delayed entry/exit from the Backdoor. I am assuming the kitchen windows would also be on the delay since they are wired in zone 3 along with backdoor but I'm not concerned about them being on the delay too.
>
> So will this work? or because the windows being on same zone as backdoor will this create a problem other than them being delayed too that I am not aware of?
>
> Note: No motion sensor concerns as not within path to backdoor.
>
> Thank you for your help
> CF
>
>
>
>