Re: SA4142-2AD2 Keyswitch
"JoeRaisin" <joeraisin2001@xxxxxxxxx> wrote in message
news:mk019r$ebg$2@xxxxxxxxxxxxxxxxxxxx
> On 5/25/2015 3:09 PM, spyros wrote:
>> ?? ???????, 25 ????? 2015 - 5:13:42 ?.?. UTC+3, ? ??????? NickMark
>> ??????:
>>> On Friday, May 22, 2015 at 12:18:37 PM UTC-4, spyros wrote:
>>>> After a service call i came across an old legacy sa4142-2ad2 panel. I
>>>> want to arm the
>> system with keyswitch from panel's zone 3. I programm zone 3 as 21 (away
>> arm) but cannot
>> save my selection (21). Any idea? Thanks in advance!
>>>
>>> Think you also have to identify which partition it arms
>>
>> I already did it on address 15 The problem is that on zone definition
>> cannot write 21 (away arm)...
>>
>
> I believe you need to make the zone a "keyswitch".
>
> I'm not certain about that - but it may also be that you can only do it
> with a particular zone.
>
If the SA4142-2AD2 is a Vista 40 which I think it is then as far as I can
tell it has to be zone 7
You enable the keyswitch zone in 15, which changes the zone type in zone 7
to Type 10 interior w/delay.
If you try to change zone 7 type to anything else in compass a message
appears
"Keyswitch operation is currently enabled, therefore Zone 7 must have a
response type of 10. Any other value will violate keyswitch configuration"
So it looks like once you enable keyswitch in #15 then zone 7 will act as a
keyswitch zone as long as you leave it as type 10 Interior w/delay .
Its very weird but try it and see.
Zone types 20,21,22 may be for wireless zones or keyfobs, I don't know
Doug