[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DLS PCLINK CONNECTION



=CE=A4=CE=B7 =CE=A3=CE=AC=CE=B2=CE=B2=CE=B1=CF=84=CE=BF, 14 =CE=A3=CE=B5=CF=
=80=CF=84=CE=B5=CE=BC=CE=B2=CF=81=CE=AF=CE=BF=CF=85 2013 6:28:20 =CE=BC.=CE=
=BC. UTC+3, =CE=BF =CF=87=CF=81=CE=AE=CF=83=CF=84=CE=B7=CF=82 Chris =CE=AD=
=CE=B3=CF=81=CE=B1=CF=88=CE=B5:
> On Friday, September 13, 2013 8:42:05 PM UTC-7, spyros wrote:
>=20
> >=20
>=20
> > The DLS is v1.2 and the panel is PC1404 v1.1 Via modem (MD12) through p=
hone line i have no problem. I am downloding the panel great.
>=20
>=20
>=20
>=20
>=20
> I haven't worked with the 1404 panel, as I simply don't see the point of =
using one instead of an 1832 or 1616, but I assume it would work the same w=
ay.
>=20
>=20
>=20
> I assume by DLS v1.2 that you mean DLS5 v1.2.  I've worked with DLS2002 f=
or many years, which prompts you to go to the keypad and start a download c=
onnection.  DLS5, however, just sits there and expects you to know this alr=
eady.  (This would be the point where a lurker from DSC should be reading t=
his and start working on changing this in the next update of DLS5.)
>=20
>=20
>=20
> So when you get to that point where it's just sitting there and you expec=
t it to do something, go to the keypad, enter installers programming, and s=
tart the download connection from there.  The 1404 may be different, but in=
 the 1832 it's in section 499.
>=20
>=20
>=20
> *8, installer code, 499, installer code, 499.  The keypad will give a few=
 extra beeps and the DLS software will continue to connect and you can go f=
rom there.
>=20
>=20
>=20
> - Chris

I didn't knew that (499 section) I am new in DSC. Yes the software is DLS5 =
v1.2
I'll try on the bench in an hour an i'll let you know if it is the same wit=
h 1832. 1616 and 1832 also i made the dl via MD12. Its the first time i dec=
ide to local dl with pclink...