[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: 7845i and Total Connect
On Jan 1, 8:37=A0pm, mleuck <m.le...@xxxxxxxxx> wrote:
> On Jan 1, 11:17=A0am, nick markowitz <nmarkow...@xxxxxxxxx> wrote:
>
>
>
> > On Jan 1, 3:59=A0am, mleuck <m.le...@xxxxxxxxx> wrote:
>
> > > On Dec 31 2010, 1:54=A0pm, "Christopher Glaeser" <c...@xxxxxxxxxxxxx>
> > > wrote:
>
> > > > When using the Vista 20P with 7845i and a Total Connect monitoring =
service,
> > > > is it possible to receive text messages for low priority faults (e.=
g.
> > > > outdoor PIR for front door delivery) while the system is armed and =
away? =A0In
> > > > other words, create a two tiered system where I receive text messag=
es for
> > > > outdoor events and the CS is notified for indoor alarms?
>
> > > > Best,
> > > > Christopher
>
> > > Yes you could assuming the outdoor PIR is programmed not to set off
> > > the rest of the system
>
> > The 24 hr montior zone is handy for that
>
> No it wouldn't, it would trigger the panel send an E150 auxiliary
> panic alarm, he's better off with a type 23 No Alarm Response
Your right the 23 type would be better and have it trigger a
chime,relay etc.
the 24 hr ones I use at radio station to alert me to non burg issues
which need attention like tower lights out, low or high temps ,etc.
very handy zone.