[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: 4140 XMPT2 open/close reports



On Feb 17, 12:29=A0pm, proguard <sp.kintzoni...@xxxxxxxxxxx> wrote:
> On 17 =D6=E5=E2, 21:27, proguard <sp.kintzoni...@xxxxxxxxxxx> wrote:
>
> > Anyone knows in which address we enable open/close for users 2 and up?
> > (not for user 1 the installer in address 39). While i close the system
> > with tech close it reports fine in contact id but with user #2 nothing
> > happens....
> > thanks boys in advance ;-)
>
> PS: in address 81 i programm everything with 1


address 81 put ones in for open and close reports,  assuming you are
reporting contact ID.

Then if I remember right, you need to enable open/close reports for
each user as you add them.  If you are using the download software you
check the open/close box for each user in user code programming.


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home