[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC random expansion trouble



On Nov 8, 6:15=A0am, motley me <to...@xxxxxxxxxxxxxxxxxxxxxx> wrote:
> Frank Kurz <t...@xxxxxxxxxxxxx> wrote innews:39OdnSxvh48MTEvRnZ2dnUVZ_rGd=
nZ2d@xxxxxxxxxxxx:
>
> > n addition to what RHC has suggested, check to see if you've enabled
> > the keypad tamper switch at the rear of the keypad. =A0If the wall's no=
t
> > "true" or the mounting plate is loose you may wind up with intermittent
> > troubles like this. =A0Also make sure all the attached keypads are
> > responding and have separate addresses. =A0Download the system log and =
see
> > if you can trace the trouble that way. =A0The next thing to do is repla=
ce
> > the common control board and reprogram your system from scratch.
>
> Only one keypad and no tamper on it. I have replaced the module that the
> buffer says is ausing the issue, but still having the issue.
>
> Reprogramming the main board won't be from scratch, I have the program
> saved to my laptop.

I think the point is that you SHOULD program it from scratch. Could be
just some little glitch in the present program that you'd just program
into the new board and have the same problem.


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home