Re: Problem with Scantronic avenger VI



"nick markowitz" <nmarkowitz@xxxxxxxxx> a écrit dans le message de groupe de
discussion :
18a83987-9464-4eca-84f9-513837006463@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> On Aug 26, 4:41 pm, Jim <alarmi...@xxxxxxx> wrote:
>> On Aug 26, 1:49 pm, Euh <Euh...@xxxxxxxxxxx> wrote:
>>
>> > Hello all,
>>
>> > We have an AV6000 that is not working well.
>> > Upon simulating an intrusion, the alarm will only make a short
>> > "blip" (1 or 2 sec at most)
>> > and then stop (and nothing is sent to the central).
>>
>> > When we simulate a power outing (by cutting the breaker), the central
>> > does get a warning so it's not like
>> > a communication problem
>>
>> > Can this be a configuration problem ?
>>
>> I just thought about it again and it could be a bad (shorted) siren
>> speaker or siren driver or self contained siren which ever one you
>> might have. But I would hope there would be a fuse on the board that
>> would blow if this were the cause.
>
> Im thinking along same line you are jim could be battery av6000 is
> pretty old panel.

Old?? its prehistoric!!