[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Ademco 15p and AD-2001 Dialer



"carolinaoff" <jbringolf1@xxxxxxxxxxxxxx> wrote in message
news:6a923$4a0b74d5$471c6679$25679@xxxxxxxxxxxxx
> Have a 15p using a 4204 relay module connected to a AD-2001 dialer. When the
> alarm trips it calls the programed number OK but hangs up immediately. 15p
> is set to 2 second close on alarm. Any hints on why the AD-2001 does not
> play the OGM. Thanks JB

Set the relay to remain transferred for 10 minutes or more.

--

Regards,
Robert L Bass

==============================>
Bass Home Electronics
DIY Alarm and Home Automation Store
http://www.bassburglaralarms.com
Sales & Service 941-870-2310
Fax 941-870-3252
==============================>