Re: ADEMCO 4110 Panic alarm
bGhasseml wrote:
>We are not very familiar with alarm systems.
>I am resetting an alarmsystem (Ademco 4110) after fixing all circuits.
>systems resets and ready. But as soon as we arm it (after 15 secon) alarm
>goes off with code 9 + BAT
>
>But battery reads good charg 13.5 VDC.
Are you reading the batt. voltage while it's plugged in to the panel? That
won't work. If the batt. is over 2 years old it may need replacing.
You have to read the voltage disconnected from the panel and under a load.
Otherwise your results are really meaningless.