[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Napco Gem-Trans2 Bug
Are they supervised..probably right...do they keep trying to send a
supervisory signal if it doesn't get through on 1st try or does it wait till
the next supervisory check in time?
--
**Crash Gordon**
"Bob La Londe" <nospam@xxxxxxxxx> wrote in message
news:h37u9o$66n$1@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> The first time this occurred I figured it was a one off circumstance, but
> I have had it happen a three times now.
>
> Gem-Trans2 keeps sending low battery signals. Replace battery. Restart
> receiver. Restart panel. Replace battery again, etc etc etc...
>
> Throw transmitter away and replace. Problem solved. These are with brand
> new installed transmitters with a fresh batteries reading over 3 volts
> under load.
>
> Just something I thought might benefit another installer. The time spent
> is worth more than the transmitter. If you get a low bat with a good
> battery or a fresh replace within a couple weeks just replace the
> transmitter and save the headaches.
>
>
>