JoeRaisin wrote:
> When performing PM services, how you you guys load test sealed lead acid
> batteries?
>
> I'm seeing two schools of thought around here:
>
> Some say to disconnect the AC from the panel and let it sit for one
> minute, then check to ensure the battery has dropped less than 1 volt.
>
> Some say to disconnect the battery from the panel check the voltage the
> battery holds at, connect a 1 amp load for a minute, remove the load and
> ensure the voltage has dropped less than 1 volt.
>
> For the most part I am talking about household systems generally using
> FA162's-168's or commercial situations using fire rated vista's or first
> alerts.
>
> Thoughts?


Canadian Tire (sorry, it's a "Canadian" company) sells this really nifty
12 volt battery load meter.  It actually places a one amp load across
the battery and gives you a voltage reading.  Elk sells a battery tester
but FWIW, I'd go with the $15.00 CT special...  :-)