[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: alarm questions for DSC PC2500



G. Morgan wrote:

>Stanley wrote:
>
>>I have asked a question in http://groups.google.com/group/alt.home.repair/browse_thread/thread/366b9af13f6986c4#
>>. Basically, I'm confused on the procedures that I have to replace my
>>fully charged SLA battery (in the progress of recharging overnight
>>right now) in order for my home alarm not to "trigger". It would be
>>much appreciated to receive any recommendations that you might have.
>>Thanks.
>
>Is the "trouble" light on?
>
>If so..
>Press *2 and see if one of the zone LED's light up
>
>
>ZONE LIGHT  TROUBLE
>1..............Defective Stand-by Battery
>2..............AC Power Failure (see Note below)
>3..............Foil Circuit Trouble
>4..............Telephone Line Problem
>5..............Unsuccessful Communication Attempt
>6..............Bell Circuit Failure
>7..............Smoke Detector Circuit Trouble
>8..............Loss of Time on System Clock
>
>Hit # to return


BTW..


On the other NG you said the panel was completely powered down so the
clock needs resetting.

[* 6]  [ Master Code]  [1]  [4 digits(Military Time)]