[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Spectra IV not as Data Hardy as Spectra III ???
On Feb 4, 12:14=A0pm, Bob La Londe <alarm_wiz...@xxxxxxxxxxx> wrote:
> I can't seem to run 3 cameras off a KBD200A in direct mode with the
> Spectra IV over a combined wire length of 200'. =A0WHAT? =A0I've got as
> amany as 5 cameras Spectra IIIs running on one controller on other
> sites. =A0Is it a change in the cameras? =A0Are the new models more over
> sensitive? =A0Am I just experiencing a gremlin?
>
> Pelco from one guy to the next seems to be giving inconsistant advice
> also.
>
> Grrr....
>
> Up until today I've had pretty good luck with them, but somebody here
> once stated that Pelco are not one of the best PTZ MFGs. =A0Who is?
Well, I found the problem. My guy had left about a 20' service loop
at each camera. I cut out the service loop and they all started
working. Wow! Talk about sensitive. Geez. Well... I guess its
time to look at some other cameras. At the price of Pelco you would
think they would be bullet proof.