Re: Ademco 6139 with 5827BD Keypad



Turn Auto Stay off *84 = 0 (what Mark said)
Auto Stay switches arming mode to Stay if you don't open a delay door to
exit.

--
Crash Gordon
-------ouch------

<I feel like I'm diagonally parked in a parallel universe>
"Marc" <mlipovitch@xxxxxxx> wrote in message news:4702A469.70701@xxxxxxxxxx
| Thanks Neo, suggestions worked perfectly!  Leaving 6139 at address 16,
| cut red jumper in 5800TM, House ID=10 (Field 24), everything works
| beautifully!
| One other question to Neo or Group:
| When I arm the panel in AWAY mode, it seems to default to STAY all the
| time.  This bypasses the motion detector-set to Zone 04-Interior
| Follower?  I'm sure I've got something programmed wrong....
|
|
| Neo wrote:
| > Hi Marc ,
| >
| > Yes all that works
| > Address 6139 as 16 if you address it anything other than that like 17
| > enable *190 10
| > For 5800TM cut the red jumper , for 5882 receiver all dips are to off.
| > For 5827 to work just enable fields 24 as 10 in panel.
| >
| > Also do not mix with 6150rf Either you use 5882 + 5800TM or simply
| > 61550rf
| >
| >
| > Regards,
| > Neo
| >
| >
| > On Oct 1, 1:40 pm, Marc <mlipovi...@xxxxxxx> wrote:
| >
| >>        Anyone gotten one of these to work?  I realize the 6139 (older
version
| >>I think-longer vertical than horizontal), have the panel set to address
| >>16 where there is a visible display (28,29,30 = no display).  Tried
| >>cutting jumpers on the 5800TM transmitter to changes the addresses
| >>mentioned above, and making the panel non-addressable by setting to 31
| >>(=no display condition).  It is an ADT branded panel used witha Vista
| >>20P board, and seems to wrok just fine otherwise.  Also using the 5882
| >>remote RF receiver (I think it's the Canadian version, but works with
| >>all transmitters I tried it with, door/window, smoke alarm, glassbreak,
| >>etc.....also works fine with 5827BD except for indication of armed
| >>status if I change the panel to a 6150 non-alpha keypad).
| >>
| >>        This one is driving me crazy, maybe thinking of going to a more
| >>advanced keypad anyways.  Picked up the 6139 cheap at a GoodWill thrift
| >>store for a buck, and it does allow me to program the system....Any
| >>help/advice appreciated!
| >>
| >>Marc
| >
| >
| >




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home