Re: Power 632 and Motion
Take the wires off the terminals and then measure resistance
Bob Smith wrote:
> I have beating my head againts the wall trying to figure this out. I
> have a Power632 and a DSC Pet Immune PIR hooked up to Zone 2.
>
> I have zone 2 set to zone type [04] which is said to be an interior in
> the manual. When I put a ohm meter up to the common and zone 2 pins
> on the alarm witht he motion hooked u I get .00 with the meter set to
> 200 ohms and then when someone walks in front of it the ohm meter
> spikes. This tells me the motion sensor is working correctly as a
> closed circuit. The problem is that the alarm panel says that zone 2
> is open all the time, no mater if the motion sensor is on or off. If
> I short out zone 2 with the commom with a resistor it shows on the
> panel that the zone is closed.
>
> What am I missing here?
>
> Thanks!