[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Concord 4 programming



ssokoly wrote:
> Leon wrote:
>> Hi,
>>
>> I have 3 level split house with the daylight basement most vulnerable
>> to the intrusion. While I am going to have window/door sensors which
>> will be ENABLED in the STAY mode, I also want to have motion detector
>> enabled in the stay mode (basically when house is armed and we are
>> asleep upstairs) for this room only.
>>
>> If I put this motion detector to external perimeter group, then arming
>> perimeter in STAY mode will enable it.
>>
>> Problem:
>> 1. Once a while I have guest staying in this basement. When this
>> happens I don't want STAY command enable this motion detector.
>>
>>
>> Question:
>> 1. Can this be easily accomplished (with macro, etc) by some easy key
>> combination so my wife can do it, w/out me going into complex
>> programming options to configure it while guests are in?
>>
>>
>> I know that I can easily by-pass open window/door sensor and force ARM
>> operation, but I don't think I can by-pass motion sensor (since unlike
>> door, I can't just have it "opened" in the arming operation).
>>
>>
>> Thank you.
>> Leon
>>
>>
> Program your motion to sensor group 15 this will enable it to be active
> in Level 2(Stay) and Level 3 (Away). There is no way to make it either
> Stay or Away when you feel like it. Its either use Group 14 where the
> Motion will be active in Level 3(Away) or use Group 15 where it will be
> active in both arming levels. You can bypass a sensor directly, the way
> that you mention is by indirectly bypassing a sensor.
>
>
I should mention that if you program it to Group 14, and have auto stay
enabled the system will not arm to Away if you do not exit the premises.



alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home