Re: NX8V2 - Last Open Zone in Memory?
Allan is right. Another method is to bypass half the zones, leave the system disarmed and see if it continues. If it still chimes,
bypass half the rest narrowing it down until you know which zone is falsing. That's more time consuming but doesn't involve the
central station.
--
Regards,
Robert L Bass
=============================>
Bass Home Electronics
941-925-8650
4883 Fallcrest Circle
Sarasota · Florida · 34233
http://www.bassburglaralarms.com
=============================>
"Allan Waghalter" <awaghalter@xxxxxxxxxxx> wrote in message news:7_qHh.1054$FG1.239@xxxxxxxxxxxxxxxxxxxxxxxxxxxxx
> Nope...
> History only for genuine events. Opening doesn't qualify.
> Go ahead and arm the system and find out what is causing the fault. You can notify central station to put you on test for a given
> amount of time so you don't create a dispatch out of a problem zone.
>
> "Foveator" <Foveator@xxxxxxxxx> wrote in message news:1173237048.398854.47690@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
>>I have a system that has been very occasionally falsing while not
>> armed (the chime went off, but no zone was open). Had it been armed,
>> the info on the open zone would have been sent to the dispatch center.
>>
>> Since the system was not armed, by the time I get to the keypad, a
>> NX-148E, there is no mention of what zone was open so I can't identify
>> and troubleshoot the sensor.
>>
>> Is there a way to display the last open zone from my keypad?
>>
>
>