Re: DSC 4020 with PC4401 DVAC Card
I believe the SIA code from the 4401 has partition identifier so the CS
automation software can pick them. Failing that, the CS can route the
specific signal from the second partition to a virtual account ID. i.e. Zone
1 to Zone 32 belongs to account ID 98 and they can stay, and Zone 33 to Zone
64 can be routed to account ID 99 within the CS automation software.
"Martin Paterson" <mpaterson@xxxxxxxx> wrote in message
news:19CdnUmstpLHmbHbnZ2dnUVZ_vqpnZ2d@xxxxxxxxxxx
> Hello;
> I have an existing site that has a 4020 installed and is being monitored
> by DVAC's (PC4401 installed). Another client is moving into the same site
> as well and would like to have there own security system. The existing
> client has no problem with sharing the current system with the new client.
> The decision to add the new client as a partition on to the existing
> system was chosen. We created a new account for the new client and added
> it into there respective partition. Unfortunately It appears that the
> DVAC card can only support one account code from what I could get out of
> the manual. Any signal I generate on the new partition always comes in on
> the original account. Has anybody found a way to add two account codes to
> the 4401 module and get it to match that of the partitions