[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Safewatch Pro 2000
If you didn't get an installer code your dead in the water.
"Tim Taylor" <fonman76@xxxxxxxxxxx> wrote in message
news:ncKdnQxDV9um3oXYnZ2dnUVZ_tCdnZ2d@xxxxxxxxxxxxxxxx
|
| "Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
| news:45183d19$0$10296$815e3792@xxxxxxxxxxxxxxxxx
| > inline
| >
| >
| > "Tim Taylor" <fonman76@xxxxxxxxxxx> wrote in message
| > news:IpqdndEnYvDhuYXYnZ2dnUVZ_vOdnZ2d@xxxxxxxxxxxxxxxx
| > | Ok, I was doing a search a while ago trying to find out how to disable
a
| > | door sensor and put a motion in its place. I found someone had said to
| > put
| > | in a code and go from there, after powering off the unit. I did as it
| > said,
| > | now there is nothing on the display. It's just used as a local. Any
| > ideas
| > or
| > | help? TIA
| > |
| > | The code is as follows:
| > |
| > | press 1 & 3 at the same time
| > |
| > | press 16*
| >
| > *16* sets the keypad address for the keypad you are working on.
| >
| > |
| > | press * # together
| > |
| > | press #20
| >
| > all this does is read out the installer code if you can see the
installer
| > code then you're ok to program the panel - if you did not see anything
| > after *# then the panel is locked. To be more clear...upon power up
after
| > hitting *# the display should say 20, then push #20 to read out the
| > installer code.
| >
| > IF you were able to get to the installer code then change it to
something
| > you want...
| > *20 1234 beep (that would change it to 1234...the beep tells you it was
| > accepted)
| >
| > now you have to go to *56...but you *need* a programming keypad to get
| > there
| > (6139 or 6160)
| > then you can follow along in the programming manual and find the old
zone
| > you want to change..you'll change the zone type to 04.
| >
| > have you changed to wiring yet?
|
|
| Thanks flash. I wasn't real sure what that code was going to do for me,
but
| I did find out. I'm completely out of service. When I hold the 1 and 3
down,
| the display will come up 16. When I push anything else it goes blank. I
| guess I've really screwed this one up.
| I couldn't get the installer code BTW.
| Changed to wiring?? Aint following you there.
|
|
|
|