Re: The Fire Alarm experts Strike Again



New CO for a new tenant? I would think only if new TI was done and permit
was issued...othewise how?


"Roland Moore" <roland@xxxxxxxxxxxx> wrote in message
news:gf51h.33271$ta3.32747@xxxxxxxxxxxxxxxxxxxxxxx
|I can only relate to what I have experienced. If someone had just moved in
| that means a new CO right? That means the AHJ must have just had it tested
| and tagged in the not too distant past to obtain the CO. There had to be
| some tags on the system if it was already installed showing last test
date,
| results etc. Seems that would be fairly fresh on everyones mind. This
might
| be a "whodunit" with an unhappy ending for someone.
|
|
| "nick markowitz" <nick-markowitz@xxxxxxxxxxx> wrote in message
| news:Iw31h.14901$DH5.13681@xxxxxxxxxxx
| > Friend of mine asked me to install a Burglar alarm at a  large retail
| > store which the place he works for just recently moved to after losing
| > there previous lease.
| > The store is fully sprinklered and has a fire system by another large
| > Burg/Fire installing company and I made sure before starting that he
realy
| > wanted me to do the burg alarm and not the company that did the fire
work.
| > He said he did not want them doing the burg.work becuse he was
displeased
| > with how the fire system was put in.
| > The store owner has an electronics backround so he had an inkling things
| > were not done properly.
| > After I get my  burg system installed and working  the sales (pig) rep
| > shows up from other company upset they did not get the burg work and
said
| > I installed used products and they were all obsolete. mind you what I
| > installed was all new Honeywell  and some of it was beta products not
even
| > on the market yet.
| > The sales (Pig) Rep was shown the door and 3 days ago
| > a small flash fire developed when chemichals flashed over in a utilty
room
| > and luckily fire dept responded when smoke went off  but system it self
| > never sounded. only keypad beeped.
| > tech from fire company came out and found wire on horn circuit was not
| > hooked to panel.Horn ciruit was never supervised.
| > So much for there superior systems and installs.
| > seems like these fire experts never learn.
| > and now the AHJ is not to pleased abiut the situation.
| >
| >
|
|