Re: Natural gas detectors and Co detectors
I HATE zone doubling.
I just took over a 20P that was zone doubled and the orig installing co.
obviously didn't understand it because all the doubled zone descriptions
were flipped...so they'd have a problem on zone 2 and tell t he homeowner to
check the door...when it really was the glassbreak in the bathroom.
Sheesh..if you're gonna do that crap you oughta at least understand it.
--
Rob Giordano
Microsoft MVP - FrontPage
"Jim Rojas" <jrojas@xxxxxxxxxxxx> wrote in message
news:46e4198c$0$10412$4c368faf@xxxxxxxxxxxxxxxxx
|I had my Vista20P originally setup for zone doubling. I had my 2 wire
| smokes on zone 1. I was still able to use zone 9 as a wireless zone. But
| soon afterwards, I threw in a 4219 to keep things simple. I am no fan of
| zone doubling.
|
| Jim Rojas
|
|
|
|
| Mark Leuck wrote:
| > Fault as in alarm? If you are using Contact ID I'd say a 151 Gas
Detection
| > should work. Honeywell says it's a bad idea to program fire on a zone
thats
| > set for zone doubling and the same if on a zone expander. For those use
the
| > panel's built-in zones
| >
| > <paul@xxxxxxxxxxxxx> wrote in message
| > news:1189346248.446114.307000@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| >> I use Ademco Vista 20p panels. I need to add 2 Co detectors and 2
| >> Natural gas detectors.
| >> Ademco has a Co type for fault reporting, but I do not see a Natural
| >> gas faul code. What do you guys use?
| >>
| >> Also can I put all 4 detectors on a zone expander? The manual says
| >> don't use zone doubling and Ademco Tech said don't use expansion
| >> module but he seemed a bit confused when I asked him why. Anybody
| >> know why? Thanks Paul.
| >>
| >
| >