[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Gemini P3200 and RP1CAe2 keypad



The version I see.. on the sticker beside the master security code says
v30B. The panel and keypads are all new. I noted this problem with the
stuff just sitting on a table and temporarily connecting a keypad and
the power, and using the PCI-mini to program. I can just return it, but
I wanted to ensure it wasn't something I did... although from all the
P3200's.. I've done, I've never seen this.

Thanks :)

jewellfish wrote:
> Michelle,
>
> May want to check the install manual for the 3200.  There are issues of
> compatability between panel and keypads...not all rp1cae2 keypad are
> compatible with all versions of the the 3200.
>
> 3200 v 40 and higher requires keypads be version 8c.
>
> Check the manual for more info.
>
> Regards Jewellfish
>
> Michelle wrote:
>> In doing a new installation with a P3200 panel and RP1CAe2 keypad, I
>> noticed that the even though the keypad works fine, the characters are
>> sometimes garbled.
>>
>> For instance the date/time on the LCD is:  06#08#06 04*50PM
>>
>> instead of:  06/08/06 04:50PM
>>
>> The keypad is fine because I tried three of them with the same results.
>>
>> Other menu areas on the keypad are garbled as well but not when you
>> configure the keypad.
>>
>> Any ideas?
>


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home