>I have a CCTV customer who is looking for me to run his alarm wire while I
> run my RG59.  For GB's & motions I am guess 4 conductor unshielded 18
> gauge
> is the way to go.  For door contacts I am guessing 2 conductor 18 guage
> unshielded.  Do most of you guys just run 4 conductor everywhere for
> purposes of time and in the odd chance you need a spare pair?  Thanks..
> not
> looking to do this on a regular basis..

Unless the runs are especially long, most installers use 22/4 for glass
breaks and motion detectors.  Although magnetic contacts only require 2
conductors, I always ran 4-wire cable to them as well.  As you surmised, it
can come in handy in case you need to add something later or in the event a
staple goes awry during the prewire.  Be sure you home run each detector.

--