[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

I printed my DLS log file. Help.



So all of you don't think I'm lying, here is what I did.

I built one of the PC Link cables, downloaded the DLS software and logged
into the alarm system.  Here is the printout of the entire system.

What am I missing?

$File=C:\DLS\Folders\ramos\kljkl.1801
$File_id=Wireless Module/Version RF5501 5.0NA
$Date=5:13:47 PM 8/5/2006
Customer Information
Company,
Contact,
Department,
Extension,
Address,
City,
Province/State,
Postal/Zip Code,
Voice Telephone Number,
Email Address,
Panel Telephone Number:, 9999999999
Additional Comments,

$Table=Module Version
Module Version,Version 5.0

$Table=Wireless Zone Serial Numbers [01]...[32]
Zone,5 or 6,Serial Number,Zone,5 or 6,Serial Number
Zone 01,6,277373,Zone 17,5,000000
Zone 02,5,000000,Zone 18,5,000000
Zone 03,5,000000,Zone 19,5,000000
Zone 04,5,000000,Zone 20,5,000000
Zone 05,5,000000,Zone 21,5,000000
Zone 06,5,000000,Zone 22,5,000000
Zone 07,5,000000,Zone 23,5,000000
Zone 08,5,000000,Zone 24,5,000000
Zone 09,5,000000,Zone 25,5,000000
Zone 10,5,000000,Zone 26,5,000000
Zone 11,5,000000,Zone 27,5,000000
Zone 12,5,000000,Zone 28,5,000000
Zone 13,5,000000,Zone 29,5,000000
Zone 14,5,000000,Zone 30,5,000000
Zone 15,5,000000,Zone 31,5,000000
Zone 16,5,000000,Zone 32,5,000000

$Table=Wireless Key Serial Numbers [41]...[56]
Key,5 or 6,Serial Number
Wireless Key 01,5,000000
Wireless Key 02,5,000000
Wireless Key 03,5,000000
Wireless Key 04,5,000000
Wireless Key 05,5,000000
Wireless Key 06,5,000000
Wireless Key 07,5,000000
Wireless Key 08,5,000000
Wireless Key 09,5,000000
Wireless Key 10,5,000000
Wireless Key 11,5,000000
Wireless Key 12,5,000000
Wireless Key 13,5,000000
Wireless Key 14,5,000000
Wireless Key 15,5,000000
Wireless Key 16,5,000000

$Table=Partition 1 Wireless Key Options [61]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 2 Wireless Key Options [62]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 3 Wireless Key Options [63]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 4 Wireless Key Options [64]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 5 Wireless Key Options [65]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 6 Wireless Key Options [66]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 7 Wireless Key Options [67]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Partition 8 Wireless Key Options [68]
Wireless Key,Option
Function Key 1,(03) Stay Arm
Function Key 2,(04) Away Arm
Function Key 3,(27) Disarm
Function Key 4,(30) Panic Alarm

$Table=Wireless Key Partition Assignments [69]
Wireless Key #01 Partition Assignment,Partition 1
Wireless Key #02 Partition Assignment,Partition 1
Wireless Key #03 Partition Assignment,Partition 1
Wireless Key #04 Partition Assignment,Partition 1
Wireless Key #05 Partition Assignment,Partition 1
Wireless Key #06 Partition Assignment,Partition 1
Wireless Key #07 Partition Assignment,Partition 1
Wireless Key #08 Partition Assignment,Partition 1
Wireless Key #09 Partition Assignment,Partition 1
Wireless Key #10 Partition Assignment,Partition 1
Wireless Key #11 Partition Assignment,Partition 1
Wireless Key #12 Partition Assignment,Partition 1
Wireless Key #13 Partition Assignment,Partition 1
Wireless Key #14 Partition Assignment,Partition 1
Wireless Key #15 Partition Assignment,Partition 1
Wireless Key #16 Partition Assignment,Partition 1

$Table=PGM Output 1 Option [70]
PGM Output 1 Option,Main Panel PGM 1

$Table=PGM Output 2 Option [71]
PGM Output 2 Option,Main Panel PGM 2

$Table=PGM 1 Activation Time [72]
PGM 1 Output Activation Time,00,05,MM:SS

$Table=PGM 2 Activation Time [73]
PGM 2 Output Activation Time,00,05,MM:SS

$Table=Wireless Supervisory Window [81]
RF Transmitter Supervisory Window,16

$Table=Zone Transmitter Supervision Options 1 to 8 [82]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,Zone 01 Supervision Enabled,Zone 01 Supervision Disabled
Disabled,2,Zone 02 Supervision Enabled,Zone 02 Supervision Disabled
Disabled,3,Zone 03 Supervision Enabled,Zone 03 Supervision Disabled
Disabled,4,Zone 04 Supervision Enabled,Zone 04 Supervision Disabled
Disabled,5,Zone 05 Supervision Enabled,Zone 05 Supervision Disabled
Disabled,6,Zone 06 Supervision Enabled,Zone 06 Supervision Disabled
Disabled,7,Zone 07 Supervision Enabled,Zone 07 Supervision Disabled
Enabled,8,Zone 08 Supervision Enabled,Zone 08 Supervision Disabled

$Table=Zone Transmitter Supervision Options 9 to 16 [83]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Zone 09 Supervision Enabled,Zone 09 Supervision Disabled
Disabled,2,Zone 10 Supervision Enabled,Zone 10 Supervision Disabled
Disabled,3,Zone 11 Supervision Enabled,Zone 11 Supervision Disabled
Disabled,4,Zone 12 Supervision Enabled,Zone 12 Supervision Disabled
Disabled,5,Zone 13 Supervision Enabled,Zone 13 Supervision Disabled
Disabled,6,Zone 14 Supervision Enabled,Zone 14 Supervision Disabled
Disabled,7,Zone 15 Supervision Enabled,Zone 15 Supervision Disabled
Disabled,8,Zone 16 Supervision Enabled,Zone 16 Supervision Disabled

$Table=Zone Transmitter Supervision Options 17 to 24 [84]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Zone 17 Supervision Enabled,Zone 17 Supervision Disabled
Disabled,2,Zone 18 Supervision Enabled,Zone 18 Supervision Disabled
Disabled,3,Zone 19 Supervision Enabled,Zone 19 Supervision Disabled
Disabled,4,Zone 20 Supervision Enabled,Zone 20 Supervision Disabled
Disabled,5,Zone 21 Supervision Enabled,Zone 21 Supervision Disabled
Disabled,6,Zone 22 Supervision Enabled,Zone 22 Supervision Disabled
Disabled,7,Zone 23 Supervision Enabled,Zone 23 Supervision Disabled
Disabled,8,Zone 24 Supervision Enabled,Zone 24 Supervision Disabled

$Table=Zone Transmitter Supervision Options 25 to 32 [85]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Zone 25 Supervision Enabled,Zone 25 Supervision Disabled
Disabled,2,Zone 26 Supervision Enabled,Zone 26 Supervision Disabled
Disabled,3,Zone 27 Supervision Enabled,Zone 27 Supervision Disabled
Disabled,4,Zone 28 Supervision Enabled,Zone 28 Supervision Disabled
Disabled,5,Zone 29 Supervision Enabled,Zone 29 Supervision Disabled
Disabled,6,Zone 30 Supervision Enabled,Zone 30 Supervision Disabled
Disabled,7,Zone 31 Supervision Enabled,Zone 31 Supervision Disabled
Disabled,8,Zone 32 Supervision Enabled,Zone 32 Supervision Disabled

$Table=General Options [90]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,For Future Use
Disabled,2,For Future Use
Disabled,3,For Future Use
Disabled,4,For Future Use
Disabled,5,For Future Use
Enabled,6,Keypad Zone Enable,PGM 2 Output Enable
Enabled,7,RF Jam Doesn't Initiate Trouble,RF Jam Initiates Trouble
Disabled,8,Global Placement Test,Individual Placement Test

$Table=RF Jam Detect Zone [93]
RF Jam Detect Zone,00,Valid Entries 1-32 (00 Jam Detect Disabled)

$File=C:\DLS\Folders\ramos\kljkl.dsc
$File_id=PC1555MX/Version 2.3
$Date=5:13:47 PM 8/5/2006
Customer Information
Company,
Contact,
Department,
Extension,
Address,
City,
Province/State,
Postal/Zip Code,
Voice Telephone Number,
Email Address,
Panel Telephone Number:, 9999999999
Additional Comments,

$Table=User Access Codes
Access Code,Code,Enabled,Bypass,Bell,Escort,Comments,*
Code 01,AAAA,No,No,No,No,
Code 02,AAAA,No,No,No,No,
Code 03,AAAA,No,No,No,No,
Code 04,AAAA,No,No,No,No,
Code 05,AAAA,No,No,No,No,
Code 06,AAAA,No,No,No,No,
Code 07,AAAA,No,No,No,No,
Code 08,AAAA,No,No,No,No,
Code 09,AAAA,No,No,No,No,
Code 10,AAAA,No,No,No,No,
Code 11,AAAA,No,No,No,No,
Code 12,AAAA,No,No,No,No,
Code 13,AAAA,No,No,No,No,
Code 14,AAAA,No,No,No,No,
Code 15,AAAA,No,No,No,No,
Code 16,AAAA,No,No,No,No,
Code 17,AAAA,No,No,No,No,
Code 18,AAAA,No,No,No,No,
Code 19,AAAA,No,No,No,No,
Code 20,AAAA,No,No,No,No,
Code 21,AAAA,No,No,No,No,
Code 22,AAAA,No,No,No,No,
Code 23,AAAA,No,No,No,No,
Code 24,AAAA,No,No,No,No,
Code 25,AAAA,No,No,No,No,
Code 26,AAAA,No,No,No,No,
Code 27,AAAA,No,No,No,No,
Code 28,AAAA,No,No,No,No,
Code 29,AAAA,No,No,No,No,
Code 30,AAAA,No,No,No,No,
Code 31,AAAA,No,No,No,No,
Code 32,AAAA,No,No,No,No,
Duress Code 33,AAAA,No,No,No,No,
Duress Code 34,AAAA,No,No,No,No,
System Master ,4337,Yes,Yes,No,Yes,
Supervisor Code 41,AAAA,No,No,No,No,
Supervisor Code 42,AAAA,No,No,No,No,

$Table=Zone 1 to 8 Definitions [001]
Zone,Definition,Comments
Zone 01,(03) Instant,
Zone 02,(00) Null Zone (Not Used),
Zone 03,(00) Null Zone (Not Used),
Zone 04,(00) Null Zone (Not Used),
Zone 05,(00) Null Zone (Not Used),
Zone 06,(00) Null Zone (Not Used),
Zone 07,(00) Null Zone (Not Used),
Zone 08,(00) Null Zone (Not Used),

$Table=Zone 9 to 16 Definitions [002]
Zone,Definition,Comments
Zone 09,(00) Null Zone (Not Used),
Zone 10,(00) Null Zone (Not Used),
Zone 11,(00) Null Zone (Not Used),
Zone 12,(00) Null Zone (Not Used),
Zone 13,(00) Null Zone (Not Used),
Zone 14,(00) Null Zone (Not Used),
Zone 15,(00) Null Zone (Not Used),
Zone 16,(00) Null Zone (Not Used),

$Table=Zone 17 to 24 Definitions [003]
Zone,Definition,Comments
Zone 17,(00) Null Zone (Not Used),
Zone 18,(00) Null Zone (Not Used),
Zone 19,(00) Null Zone (Not Used),
Zone 20,(00) Null Zone (Not Used),
Zone 21,(00) Null Zone (Not Used),
Zone 22,(00) Null Zone (Not Used),
Zone 23,(00) Null Zone (Not Used),
Zone 24,(00) Null Zone (Not Used),

$Table=Zone 25 to 32 Definitions [004]
Zone,Definition,Comments
Zone 25,(00) Null Zone (Not Used),
Zone 26,(00) Null Zone (Not Used),
Zone 27,(00) Null Zone (Not Used),
Zone 28,(00) Null Zone (Not Used),
Zone 29,(00) Null Zone (Not Used),
Zone 30,(00) Null Zone (Not Used),
Zone 31,(00) Null Zone (Not Used),
Zone 32,(00) Null Zone (Not Used),

$Table=System Times [005]
Entry Delay 1,030,Seconds
Entry Delay 2,045,Seconds
Exit Delay,120,Seconds
Bell Cut-Off,004,Minutes

$Table=Auto Arm Time
System,9999,Valid entries are 0000-2359, 9999 to Disable

$Table=Installer's Code [006]
Installer's Code,4337

$Table=Master Code [007]
Master Code,4337

$Table=Maintenance Code [008]
Maintenance Code,AAAA,Enter Decimal Data (AAAA or AAAA00 to disable)

$Table=PC1555MX PGM's 1 & 2 (Onboard) [009]
Attributes,Definition
PGM 01,(19) (*71) Command Output #1
PGM 02,(10) System Event

$Table=PC5208 PGM's 3 to 10 [010]
Attributes,Definition
PGM 03,(01) Fire and Burglary Bell Output
PGM 04,(01) Fire and Burglary Bell Output
PGM 05,(01) Fire and Burglary Bell Output
PGM 06,(01) Fire and Burglary Bell Output
PGM 07,(01) Fire and Burglary Bell Output
PGM 08,(01) Fire and Burglary Bell Output
PGM 09,(01) Fire and Burglary Bell Output
PGM 10,(01) Fire and Burglary Bell Output

$Table=PC5204 PGM's 11 to 14 [011]
Attributes,Definition
PGM 11,(01) Fire and Burglary Bell Output
PGM 12,(01) Fire and Burglary Bell Output
PGM 13,(01) Fire and Burglary Bell Output
PGM 14,(01) Fire and Burglary Bell Output

$Table=Keypad Lockout Options [012]
Number Invalid Codes Before Lockout,000,000-255 Invalid Codes
Lockout Duration,000,000-255 Minutes

$Table=First System Option Code [013]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Normally Closed Loops,End-Of-Line Resistors
Disabled,2,Double End-Of-Line Resistors,Single End-Of-Line Resistors
Enabled,3,Panel Shows All Troubles While Armed,Panel Shows Only Fire
Troubles While Armed
Disabled,4,Tampers/Faults Do Not Show As Open,Tampers/Faults Show As
Open
Disabled,5,For Future Use
Enabled,6,Audible Exit Fault Enabled,Audible Exit Fault Disabled
Enabled,7,Event Buffer Follows Swinger Shutdown,Event Buffer Logs
Events Past Shutdown
Disabled,8,Temporal Three Fire Signal Enabled,Standard Pulsed Fire
Signal

$Table=Second System Option Code [014]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Arm/Disarm Bell Squawk Enabled,Arm/Disarm Bell Squawk
Disabled
Disabled,2,Bell Squawk During Auto Arm,No Bell Squawk During Auto Arm
Disabled,3,Bell Squawk On Exit Delay,No Bell Squawk On Exit Delay
Disabled,4,Bell Squawk On Entry Delay,No Bell Squawk On Entry Delay
Disabled,5,Bell Squawk On Trouble,No Bell Squawk On Trouble
Enabled,6,Audible Exit Beeps,Silent Exit Delay
Disabled,7,Exit Delay Termination Enabled,Exit Delay Termination
Disabled
Disabled,8,Fire Bell Is Continuous,Fire Bell Follows Bell Cut-off

$Table=Third System Option Code [015]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,[F] Key Enabled,[F] Key Disabled
Disabled,2,[P] Key Audible (Bell/Beeps),[P] Key Silent
Disabled,3,Quick Exit Enabled,Quick Exit Disabled
Enabled,4,Quick Arming Enabled,Quick Arming Disabled (Funct. Keys Req.
Code)
Disabled,5,Code Required For Bypassing,No Code Required
Disabled,6,Master Code Not Changeable,Master Code Changeable
Disabled,7,TLM Enabled,TLM Disabled
Disabled,8,TLM Audible When Armed,TLM Trouble Only When Armed

$Table=Fourth System Option Code [016]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,AC Trouble Displayed,AC Trouble Not Displayed
Disabled,2,Trouble Light Flashes if AC Fails,Trouble Light Does Not
Follow AC Status
Disabled,3,Blank Keypad When Not Used,Keypad Active Always
Disabled,4,Code Required to Remove Keypad Blanking,No Code Required
Enabled,5,Keypad Backlighting is Enabled,Keypad Backlighting is
Disabled
Disabled,6,Power Save Mode Enabled,Power Save Mode Disabled
Disabled,7,Bypass Status Displayed While Armed,Bypass Status Not
Displayed While Armed
Disabled,8,Keypad Tampers Enabled,Keypad Tampers Disabled

$Table=Fifth System Option Code [017]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,WLSKEY Does Not Use Access Codes,WLSKEY Uses Access Codes
Disabled,2,For Future Use
Disabled,3,For Future Use
Disabled,4,For Future Use
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,Squawk on Away Arming/Disarming Only,Bell Squawk on all
Arming/Disarming

$Table=Keypad Zone Assignments [020]
Keypad 1 Zone,00
Keypad 2 Zone,00
Keypad 3 Zone,00
Keypad 4 Zone,00
Keypad 5 Zone,00
Keypad 6 Zone,00
Keypad 7 Zone,00
Keypad 8 Zone,00

$Table=Zone Loop Response Option Code [030]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Zone 1 is Fast Response,Zone 1 is Normal Loop Response
Disabled,2,Zone 2 is Fast Response,Zone 2 is Normal Loop Response
Disabled,3,Zone 3 is Fast Response,Zone 3 is Normal Loop Response
Disabled,4,Zone 4 is Fast Response,Zone 4 is Normal Loop Response
Disabled,5,Zone 5 is Fast Response,Zone 5 is Normal Loop Response
Disabled,6,Zone 6 is Fast Response,Zone 6 is Normal Loop Response
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=Zone 1 to 8 Attributes [101]...[108]
Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
Zone 01,Yes,Yes,Yes,Yes,No,Yes,No,Yes,(03) Instant
Zone 02,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 03,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 04,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 05,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 06,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 07,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 08,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)

$Table=Zone 9 to 16 Attributes [109]...[116]
Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
Zone 09,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 10,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 11,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 12,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 13,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 14,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 15,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 16,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)

$Table=Zone 17 to 24 Attributes [117]...[124]
Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
Zone 17,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 18,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 19,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 20,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 21,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 22,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 23,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 24,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)

$Table=Zone 25 to 32 Attributes [125]...[132]
Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
Zone 25,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 26,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 27,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 28,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 29,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 30,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 31,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 32,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)

$Table=PC1555MX PGM 1 Attributes [141]
Output,En,N\A,True,Pul,Code,N\A,N\A,N\A
PGM 01,Yes,No,Yes,Yes,Yes,No,No,No,(19) (*71) Command Output #1

$Table=PC1555MX PGM 2 Attributes [142]
Output,Burg.,Fire,Panic,Med.,Supv.,Priority,Hldup,O/P Timer
PGM 02,Yes,Yes,Yes,Yes,Yes,Yes,Yes,No,(10) System Event

$Table=PC5208 PGM 3 Attributes [143]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 03,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 4 Attributes [144]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 04,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 5 Attributes [145]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 05,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 6 Attributes [146]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 06,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 7 Attributes [147]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 07,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 8 Attributes [148]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 08,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 9 Attributes [149]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 09,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5208 PGM 10 Attributes [150]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 10,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5204 PGM 11 Attributes [151]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 11,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5204 PGM 12 Attributes [152]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 12,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5204 PGM 13 Attributes [153]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 13,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=PC5204 PGM 14 Attributes [154]
Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
PGM 14,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output

$Table=Maximum Dialing Attempts [160]
008,Valid entries are 001-255 attempts

$Table=Post Dial Wait for Handshake [161]
040,Valid entries are 001-255 seconds

$Table=PGM Output Timer [164]
005,Valid Entries are 001-255 seconds

$Table=Zone Assignments (Zones 1-8) [202]
Zone,Setting,Option,Option Enabled,Option Disabled
Zone 01,Enabled,1,Zone 1 is Enabled,Zone 1 is Disabled
Zone 02,Disabled,2,Zone 2 is Enabled,Zone 2 is Disabled
Zone 03,Disabled,3,Zone 3 is Enabled,Zone 3 is Disabled
Zone 04,Disabled,4,Zone 4 is Enabled,Zone 4 is Disabled
Zone 05,Disabled,5,Zone 5 is Enabled,Zone 5 is Disabled
Zone 06,Disabled,6,Zone 6 is Enabled,Zone 6 is Disabled
Zone 07,Disabled,7,Zone 7 is Enabled,Zone 7 is Disabled
Zone 08,Disabled,8,Zone 8 is Enabled,Zone 8 is Disabled

$Table=Zone Assignments (Zones 9-16) [203]
Zone,Setting,Option,Option Enabled,Option Disabled
Zone 09,Disabled,1,Zone 09 is Enabled,Zone 09 is Disabled
Zone 10,Disabled,2,Zone 10 is Enabled,Zone 10 is Disabled
Zone 11,Disabled,3,Zone 11 is Enabled,Zone 11 is Disabled
Zone 12,Disabled,4,Zone 12 is Enabled,Zone 12 is Disabled
Zone 13,Disabled,5,Zone 13 is Enabled,Zone 13 is Disabled
Zone 14,Disabled,6,Zone 14 is Enabled,Zone 14 is Disabled
Zone 15,Disabled,7,Zone 15 is Enabled,Zone 15 is Disabled
Zone 16,Disabled,8,Zone 16 is Enabled,Zone 16 is Disabled

$Table=Zone Assignments (Zones 17-24) [204]
Zone,Setting,Option,Option Enabled,Option Disabled
Zone 17,Disabled,1,Zone 17 is Enabled,Zone 17 is Disabled
Zone 18,Disabled,2,Zone 18 is Enabled,Zone 18 is Disabled
Zone 19,Disabled,3,Zone 19 is Enabled,Zone 19 is Disabled
Zone 20,Disabled,4,Zone 20 is Enabled,Zone 20 is Disabled
Zone 21,Disabled,5,Zone 21 is Enabled,Zone 21 is Disabled
Zone 22,Disabled,6,Zone 22 is Enabled,Zone 22 is Disabled
Zone 23,Disabled,7,Zone 23 is Enabled,Zone 23 is Disabled
Zone 24,Disabled,8,Zone 24 is Enabled,Zone 24 is Disabled

$Table=Zone Assignments (Zones 25-32) [205]
Zone,Setting,Option,Option Enabled,Option Disabled
Zone 25,Disabled,1,Zone 25 is Enabled,Zone 25 is Disabled
Zone 26,Disabled,2,Zone 26 is Enabled,Zone 26 is Disabled
Zone 27,Disabled,3,Zone 27 is Enabled,Zone 27 is Disabled
Zone 28,Disabled,4,Zone 28 is Enabled,Zone 28 is Disabled
Zone 29,Disabled,5,Zone 29 is Enabled,Zone 29 is Disabled
Zone 30,Disabled,6,Zone 30 is Enabled,Zone 30 is Disabled
Zone 31,Disabled,7,Zone 31 is Enabled,Zone 31 is Disabled
Zone 32,Disabled,8,Zone 32 is Enabled,Zone 32 is Disabled

$Table=Communicator Telephone Numbers [301]...[303]
Phone #,Enter Telephone # (32 Digits max.)
First,D3783546FFFFFFFFFFFFFFFFFFFFFFFF
Second,FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
Third,FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF

$Table=Account Codes [310]...[311]
Telephone #,Identifier Code
Telephone #1/3 Account Code,4337
Telephone #2 Account Code,FFFF

$Table=Alarm Reporting Codes, Zones 1 to 8 [320]
Zone,Code,Zone,Code
Zone 01,FF,Zone 05,FF
Zone 02,FF,Zone 06,FF
Zone 03,FF,Zone 07,FF
Zone 04,FF,Zone 08,FF

$Table=Alarm Reporting Codes, Zones 9 to 16 [321]
Zone,Code,Zone,Code
Zone 09,FF,Zone 13,FF
Zone 10,FF,Zone 14,FF
Zone 11,FF,Zone 15,FF
Zone 12,FF,Zone 16,FF

$Table=Alarm Reporting Codes, Zones 17 to 24 [322]
Zone,Code,Zone,Code
Zone 17,FF,Zone 21,FF
Zone 18,FF,Zone 22,FF
Zone 19,FF,Zone 23,FF
Zone 20,FF,Zone 24,FF

$Table=Alarm Reporting Codes, Zones 25 to 32 [323]
Zone,Code,Zone,Code
Zone 25,FF,Zone 29,FF
Zone 26,FF,Zone 30,FF
Zone 27,FF,Zone 31,FF
Zone 28,FF,Zone 32,FF

$Table=Alarm Restoral Reporting Codes, Zones 1 to 8 [324]
Zone,Code,Zone,Code
Zone 01,FF,Zone 05,FF
Zone 02,FF,Zone 06,FF
Zone 03,FF,Zone 07,FF
Zone 04,FF,Zone 08,FF

$Table=Alarm Restoral Reporting Codes, Zones 9 to 16 [325]
Zone,Code,Zone,Code
Zone 09,FF,Zone 13,FF
Zone 10,FF,Zone 14,FF
Zone 11,FF,Zone 15,FF
Zone 12,FF,Zone 16,FF

$Table=Alarm Restoral Reporting Codes, Zones 17 to 24 [326]
Zone,Code,Zone,Code
Zone 17,FF,Zone 21,FF
Zone 18,FF,Zone 22,FF
Zone 19,FF,Zone 23,FF
Zone 20,FF,Zone 24,FF

$Table=Alarm Restoral Reporting Codes, Zones 25 to 32 [327]
Zone,Code,Zone,Code
Zone 25,FF,Zone 29,FF
Zone 26,FF,Zone 30,FF
Zone 27,FF,Zone 31,FF
Zone 28,FF,Zone 32,FF

$Table=Miscellaneous Alarm Reporting Codes [328]
Duress Alarm,FF,Zone Expander Supervisory Alarm,FF
Opening After Alarm,FF,Zone Expander Supervisory Restoral,FF
Recent Closing,FF,Cross Zone Police Code Alarm,FF

$Table=Priority Alarm and Restoral Reporting Codes [329]
Keypad [F]ire Alarm,FF,Keypad [F]ire Restoral,FF
Keypad [A]uxiliary Alarm,FF,Keypad [A]uxiliary Restoral,FF
Keypad [P]anic Alarm,FF,Keypad [P]anic Restoral,FF
PGM 2 Alarm,FF,PGM 2 Restoral,FF

$Table=Tamper Reporting Codes, Zones 1 to 8 [330]
Zone,Code,Zone,Code
Zone 01,FF,Zone 05,FF
Zone 02,FF,Zone 06,FF
Zone 03,FF,Zone 07,FF
Zone 04,FF,Zone 08,FF

$Table=Tamper Reporting Codes, Zones 9 to 16 [331]
Zone,Code,Zone,Code
Zone 09,FF,Zone 13,FF
Zone 10,FF,Zone 14,FF
Zone 11,FF,Zone 15,FF
Zone 12,FF,Zone 16,FF

$Table=Tamper Reporting Codes, Zones 17 to 24 [332]
Zone,Code,Zone,Code
Zone 17,FF,Zone 21,FF
Zone 18,FF,Zone 22,FF
Zone 19,FF,Zone 23,FF
Zone 20,FF,Zone 24,FF

$Table=Tamper Reporting Codes, Zones 25 to 32 [333]
Zone,Code,Zone,Code
Zone 25,FF,Zone 29,FF
Zone 26,FF,Zone 30,FF
Zone 27,FF,Zone 31,FF
Zone 28,FF,Zone 32,FF

$Table=Tamper Restoral Reporting Codes, Zones 1 to 8 [334]
Zone,Code,Zone,Code
Zone 01,FF,Zone 05,FF
Zone 02,FF,Zone 06,FF
Zone 03,FF,Zone 07,FF
Zone 04,FF,Zone 08,FF

$Table=Tamper Restoral Reporting Codes, Zones 9 to 16 [335]
Zone,Code,Zone,Code
Zone 09,FF,Zone 13,FF
Zone 10,FF,Zone 14,FF
Zone 11,FF,Zone 15,FF
Zone 12,FF,Zone 16,FF

$Table=Tamper Restoral Reporting Codes, Zones 17 to 24 [336]
Zone,Code,Zone,Code
Zone 17,FF,Zone 21,FF
Zone 18,FF,Zone 22,FF
Zone 19,FF,Zone 23,FF
Zone 20,FF,Zone 24,FF

$Table=Tamper Restoral Reporting Codes, Zones 25 to 32 [337]
Zone,Code,Zone,Code
Zone 25,FF,Zone 29,FF
Zone 26,FF,Zone 30,FF
Zone 27,FF,Zone 31,FF
Zone 28,FF,Zone 32,FF

$Table=Miscellaneous Tamper Reporting Codes [338]
General System Tamper,FF
General System Tamper Restoral,FF
Keypad Lockout,FF

$Table=Closing (Arming) Reporting Codes, Access Codes 1 to 8 [339]
Access Code 01,FF,Access Code 05,FF
Access Code 02,FF,Access Code 06,FF
Access Code 03,FF,Access Code 07,FF
Access Code 04,FF,Access Code 08,FF

$Table=Closing (Arming) Reporting Codes, Access Codes 9 to 16 [340]
Access Code 09,FF,Access Code 13,FF
Access Code 10,FF,Access Code 14,FF
Access Code 11,FF,Access Code 15,FF
Access Code 12,FF,Access Code 16,FF

$Table=Closing (Arming) Reporting Codes, Access Codes 17 to 24 [341]
Access Code 17,FF,Access Code 21,FF
Access Code 18,FF,Access Code 22,FF
Access Code 19,FF,Access Code 23,FF
Access Code 20,FF,Access Code 24,FF

$Table=Closing (Arming) Reporting Codes, Access Codes 25 to 32 [342]
Access Code 25,FF,Access Code 29,FF
Access Code 26,FF,Access Code 30,FF
Access Code 27,FF,Access Code 31,FF
Access Code 28,FF,Access Code 32,FF

$Table=Miscellaneous Closing (Arming) Reporting Codes [343]
Duress Code 33,FF,Supervisor Code 42,FF
Duress Code 34,FF,Partial Closing,FF
System Master,FF,Special Closing,FF
Supervisor Code 41,FF

$Table=Opening (Disarming) Reporting Codes, Access Codes 1 to 8 [344]
Access Code 01,FF,Access Code 05,FF
Access Code 02,FF,Access Code 06,FF
Access Code 03,FF,Access Code 07,FF
Access Code 04,FF,Access Code 08,FF

$Table=Opening (Disarming) Reporting Codes, Access Codes 9 to 16 [345]
Access Code 09,FF,Access Code 13,FF
Access Code 10,FF,Access Code 14,FF
Access Code 11,FF,Access Code 15,FF
Access Code 12,FF,Access Code 16,FF

$Table=Opening (Disarming) Reporting Codes, Access Codes 17 to 24 [346]
Access Code 17,FF,Access Code 21,FF
Access Code 18,FF,Access Code 22,FF
Access Code 19,FF,Access Code 23,FF
Access Code 20,FF,Access Code 24,FF

$Table=Opening (Disarming) Reporting Codes, Access Codes 25 to 32 [347]
Access Code 25,FF,Access Code 29,FF
Access Code 26,FF,Access Code 30,FF
Access Code 27,FF,Access Code 31,FF
Access Code 28,FF,Access Code 32,FF

$Table=Miscellaneous Opening (Disarming) Reporting Codes [348]
Duress Code 33,FF,Supervisor Code 42,FF
Duress Code 34,FF,Auto-Arm Cancellation,FF
System Master,FF,Special Opening,FF
Supervisor Code 41,FF

$Table=Maintenance Alarm Reporting Codes [349]
Battery Trouble Alarm,FF
AC Failure Trouble Alarm,FF
Bell Circuit Trouble Alarm,FF
Fire Trouble Alarm,FF
Auxiliary Power Supply Trouble Alarm,FF
TLM Trouble Code (via LINKS),FF
General System Trouble,FF
General System Supervisory,FF

$Table=Maintenance Restoral Reporting Codes [350]
Battery Trouble Restoral,FF
AC Failure Trouble Restoral,FF
Bell Circuit Trouble Restoral,FF
Fire Trouble Restoral,FF
Auxiliary Power Supply Trouble Restoral,FF
TLM Restoral,FF
General System Trouble Restoral,FF
General System Supervisory Restoral,FF

$Table=Miscellaneous Maintenance Reporting Codes [351]
Phone Number 1 Failure to Communicate,FF
Phone Number 2 Failure to Communicate,FF
Event Buffer is 75% Full Since Last Upload,FF
DLS Lead IN,FF
DLS Lead OUT,FF
General Zone Trouble Alarm,FF
General Zone Trouble Restoral,FF
Delinquency,FF

$Table=Test Transmission Reporting Codes [352]
Periodic Test Transmission,FF
System Test,FF
LINKS 1000 Test Transmission Code,FF

$Table=Wireless Maintenance Reporting Codes [353]
General Zone Low Battery Alarm,FF
General Zone Low Battery Restore,FF

$Table=Communicator Format Options [360]
First and Third Phone Number,(02) 20 BPS, 2300Hz Handshake
Second Phone Number,(02) 20 BPS, 2300Hz Handshake

$Table=Alarms & Restorals [361]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,First Telephone Number,Disabled
Disabled,2,Second Telephone Number,Disabled
Disabled,3,First Telephone Number (via LINKS),Disabled
Disabled,4,Second Telephone Number (via LINKS),Disabled
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=Tampers & Restorals [363]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,First Telephone Number,Disabled
Disabled,2,Second Telephone Number,Disabled
Disabled,3,First Telephone Number (via LINKS),Disabled
Disabled,4,Second Telephone Number (via LINKS),Disabled
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=Openings & Closings [365]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,First Telephone Number,Disabled
Disabled,2,Second Telephone Number,Disabled
Disabled,3,First Telephone Number (via LINKS),Disabled
Disabled,4,Second Telephone Number (via LINKS),Disabled
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=System Maintenance Alarms & Restorals [367]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,First Telephone Number,Disabled
Disabled,2,Second Telephone Number,Disabled
Disabled,3,First Telephone Number (via LINKS),Disabled
Disabled,4,Second Telephone Number (via LINKS),Disabled
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=System Test Transmissions [368]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,First Telephone Number,Disabled
Disabled,2,Second Telephone Number,Disabled
Disabled,3,First Telephone Number (via LINKS),Disabled
Disabled,4,Second Telephone Number (via LINKS),Disabled
Disabled,5,For Future Use
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=Communication Variables [370]
003,Swinger Shutdown (Alarms & Restorals),(000-255 Transmissions,
000=Disabled)
003,Swinger Shutdown (Tampers & Restorals),(000-255 Transmissions,
000=Disabled)
003,Swinger Shutdown (Maint. & Restorals),(000-255 Transmissions,
000=Disabled)
000,Communication Delay,(000-255 Seconds)
030,AC Failure Communication Delay,(001-255 minutes, 000=disabled)
003,TLM Trouble Delay,Number of valid checks required +3...000-255 x
10s
030,Test Transmission Cycle (land-line),(000-255 Days/Minutes)
030,LINKS Test Transmission Cycle,(000-255 Days)
007,Zone Low Battery Transmission Delay,(000-255 Days)
030,Delinquency Timer,(000-255 Days/Hours)

$Table=Test Transmission Time Of Day [371]
9999,Valid entries are 0000-2359, 9999 to Disable

$Table=First Communicator Option Code [380]
Setting,Option,Option Enabled,Option Disabled
Enabled,1,Communications Enabled,Communications Disabled
Disabled,2,Restorals On Bell Time Out,Restorals Follow Zones
Disabled,3,Pulse Dialing,DTMF Dialing
Enabled,4,Switch to Pulse Dialing On 5th Attempt,DTMF Dial For All
Attempts
Disabled,5,3rd Phone Number Enabled,3rd Phone Number Disabled
Disabled,6,Alternate Dial (First & 3rd),Call First Number, Backup to
3rd
Disabled,7,Call LINKS as well as Land Line,LINKS is Backup of Land
Line(s)
Disabled,8,Delinquency Follows Zone Activity (Hours),Delinquency
Follows Arming (Days)

$Table=Second Communicator Option Code [381]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Opening After Alarm Keypad Ringback Enabled,Opening After
Alarm Keypad Ringback Disabled
Disabled,2,Opening After Alarm Bell Ringback Enabled,Opening After
Alarm Bell Ringback Disabled
Disabled,3,SIA Sends Programmed Reporting Codes,SIA Sends Automatic
Reporting Codes
Disabled,4,Closing Confirmation Enabled,Closing Confirmation Disabled
Enabled,5,Talk/Listen (PC5928) on Phone #1/3 Enabled,Talk/Listen
(PC5928) on Phone #1/3 Disabled
Disabled,6,Phone 2 Listen In Enabled,Phone 2 Listen In Disabled
Enabled,7,Contact I.D. Uses Pgm'd Rep. Codes,Contact I.D. Uses Auto
Rep. Codes
Disabled,8,For Future Use

$Table=LINKS Preambles [390]...[393]
First Preamble (First Telephone Number),FFFF
Second Preamble (Second Telephone Number),FFFF
Third Preamble (Third Telephone Number),FFFF
Special Function Preamble (All Numbers),FFFFFF

$Table=First Downloading Option Code [401]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Downloading Answer Enabled,Downloading Answer Disabled
Enabled,2,User Can Enable DLS Window,User Can Not Enable DLS Window
Disabled,3,Call-Back Enabled,Call-Back Disabled
Disabled,4,User Initiated Call Up Enabled,User Initiated Call Up
Disabled
Disabled,5,Auto Event Buffer Upload Enabled,Auto Event Buffer Upload
Disabled
Disabled,6,For Future Use
Disabled,7,For Future Use
Disabled,8,For Future Use

$Table=Downloading Computer's Telephone Number [402]
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF,(32 Digits max.)

$Table=Downloading Access Code [403]
4337,Enter 4 Hexadecimal Digits

$Table=Panel Identification Code [404]
5008,Enter 4 Hexadecimal Digits

$Table=Answering Machine Double-Call Timer [405]
060,Valid entries are 001-255 Seconds

$Table=Number of Rings [406]
000,Valid entries are 000-255 Rings

$Table=LINKS Preamble (Downloading Phone Number) [490]
FFFF,All unused digits are programmed with Hex F

$Table=Automatic Clock Adjust [700]
60,Valid entries are 00-99 Seconds

$Table=First International Options Code [701]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,50 Hz AC,60 Hz AC
Disabled,2,Time Base is Internal Crystal,Time Base is AC Line
Disabled,3,AC/DC Arming Inhibit Enabled,AC/DC Arming Inhibit Disabled
Disabled,4,All System Tampers Require Installer Reset,All System
Tampers follow Restore
Disabled,5,6-Digit User Access Codes,4-Digit User Access Codes
Disabled,6,Busy Tone Detection Enabled,Busy Tone Detection Disabled
Disabled,7,High Current Battery Charge,Standard Current Battery Charge
Disabled,8,For Future Use

$Table=Second International Options Code [702]
Setting,Option,Option Enabled,Option Disabled
Disabled,1,Pulse Dialing Make/Break Ratio is 33/67,Pulse Dialing
Make/Break Ratio is 40/60
Enabled,2,Force Dialing Enabled,Force Dialing Disabled
Disabled,3,Test Transmission Interval in Minutes,Test Transmission
Interval in Days
Disabled,4,1600 Hz Handshake,Standard Handshake
Disabled,5,ID Tone Enabled,ID Tone Disabled
Disabled,6,2100 Hz ID Tone,1300 Hz ID Tone
Disabled,7,One Time 1-Hr User Enabled DLS Window,Full 6-Hr User Enabled
DLS Window
Disabled,8,Bell Enabled FTC when Armed,FTC Trouble only when Armed

$Table=Delay Between Dialing Attempts [703]
001,Valid entries are 000-255 Seconds

$Table=Zone Status
Zone,Mem,Open,Fault,Tmpr,LoBat,Bypass,Definition
Zone 01,No,No,No,No,No,No,(03) Instant
Zone 02,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 03,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 04,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 05,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 06,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 07,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 08,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 09,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 10,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 11,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 12,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 13,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 14,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 15,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 16,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 17,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 18,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 19,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 20,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 21,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 22,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 23,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 24,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 25,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 26,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 27,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 28,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 29,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 30,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 31,No,No,No,No,No,No,(00) Null Zone (Not Used)
Zone 32,No,No,No,No,No,No,(00) Null Zone (Not Used)

$Table=Arm Status
System,Disarmed

$Table=Door Chime Status
System,Disable

$Table=Auto Arm Status
System,Disable

$Table=Time & Date
Time,16,51,HH:MM
Date,08,05,06,MM/DD/YY

$Table=Trouble Status
Low Battery,No,WKEY 01 Low Bat,No,HHK 1 Low Bat,No
Bell Circuit Failure,No,WKEY 02 Low Bat,No,HHK 2 Low Bat,No
General System Trouble,No,WKEY 03 Low Bat,No,HHK 3 Low Bat,No
General System Tamper,No,WKEY 04 Low Bat,No,HHK 4 Low Bat,No
General System Supervisory,No,WKEY 05 Low Bat,No
5204 Low Battery,No,WKEY 06 Low Bat,No
5204 AC Fail,No,WKEY 07 Low Bat,No
AC Fail,No,WKEY 08 Low Bat,No
TLM Trouble,No,WKEY 09 Low Bat,No
Fail To Communicate,No,WKEY 10 Low Bat,No
Zone Fault,No,WKEY 11 Low Bat,No
Zone Tamper,No,WKEY 12 Low Bat,No
Device Low Battery,No,WKEY 13 Low Bat,No
Loss of Time,No,WKEY 14 Low Bat,No
WKEY 15 Low Bat,No
WKEY 16 Low Bat,No

$Table=Module Supervisory
Module,Enrolled,Trouble,Module,Enrolled,Trouble
Keypad 1,Yes,No,Escort 5580,No,N/A
Keypad 2,No,N/A, Alt. Comms,No,N/A
Keypad 3,No,N/A,PC59XX,No,N/A
Keypad 4,No,N/A,PC5400,No,N/A
Keypad 5,No,N/A,PC5204,No,N/A
Keypad 6,No,N/A,PC5208,No,N/A
Keypad 7,No,N/A,PC5132,Yes,No
Keypad 8,No,N/A

$Table=Keypad Lockout Status
System,No

$Table=Installer Lockout Status
System,Disable






alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home