[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DLS2002 Log File Of My System



What you appear to be missing is Customer Information, Company, Contact,
Department and the rest.

Also I doubt the panel phone number is accurate

"Larry Lipide" <lpide@xxxxxxxxxxx> wrote in message
news:UBaBg.19182$Nv.16881@xxxxxxxxxxxxx
> So all of you don't think I'm lying, here is what I did.
>
> I built one of the PC Link cables, downloaded the DLS software and logged
> into the alarm system.  Here is the printout of the entire system.
>
> What am I missing?
>
> $File=C:\DLS\Folders\ramos\kljkl.1801
> $File_id=Wireless Module/Version RF5501 5.0NA
> $Date=5:13:47 PM 8/5/2006
> Customer Information
> Company,
> Contact,
> Department,
> Extension,
> Address,
> City,
> Province/State,
> Postal/Zip Code,
> Voice Telephone Number,
> Email Address,
> Panel Telephone Number:, 9999999999
> Additional Comments,
>
> $Table=Module Version
> Module Version,Version 5.0
>
> $Table=Wireless Zone Serial Numbers [01]...[32]
> Zone,5 or 6,Serial Number,Zone,5 or 6,Serial Number
> Zone 01,6,277373,Zone 17,5,000000
> Zone 02,5,000000,Zone 18,5,000000
> Zone 03,5,000000,Zone 19,5,000000
> Zone 04,5,000000,Zone 20,5,000000
> Zone 05,5,000000,Zone 21,5,000000
> Zone 06,5,000000,Zone 22,5,000000
> Zone 07,5,000000,Zone 23,5,000000
> Zone 08,5,000000,Zone 24,5,000000
> Zone 09,5,000000,Zone 25,5,000000
> Zone 10,5,000000,Zone 26,5,000000
> Zone 11,5,000000,Zone 27,5,000000
> Zone 12,5,000000,Zone 28,5,000000
> Zone 13,5,000000,Zone 29,5,000000
> Zone 14,5,000000,Zone 30,5,000000
> Zone 15,5,000000,Zone 31,5,000000
> Zone 16,5,000000,Zone 32,5,000000
>
> $Table=Wireless Key Serial Numbers [41]...[56]
> Key,5 or 6,Serial Number
> Wireless Key 01,5,000000
> Wireless Key 02,5,000000
> Wireless Key 03,5,000000
> Wireless Key 04,5,000000
> Wireless Key 05,5,000000
> Wireless Key 06,5,000000
> Wireless Key 07,5,000000
> Wireless Key 08,5,000000
> Wireless Key 09,5,000000
> Wireless Key 10,5,000000
> Wireless Key 11,5,000000
> Wireless Key 12,5,000000
> Wireless Key 13,5,000000
> Wireless Key 14,5,000000
> Wireless Key 15,5,000000
> Wireless Key 16,5,000000
>
> $Table=Partition 1 Wireless Key Options [61]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 2 Wireless Key Options [62]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 3 Wireless Key Options [63]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 4 Wireless Key Options [64]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 5 Wireless Key Options [65]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 6 Wireless Key Options [66]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 7 Wireless Key Options [67]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Partition 8 Wireless Key Options [68]
> Wireless Key,Option
> Function Key 1,(03) Stay Arm
> Function Key 2,(04) Away Arm
> Function Key 3,(27) Disarm
> Function Key 4,(30) Panic Alarm
>
> $Table=Wireless Key Partition Assignments [69]
> Wireless Key #01 Partition Assignment,Partition 1
> Wireless Key #02 Partition Assignment,Partition 1
> Wireless Key #03 Partition Assignment,Partition 1
> Wireless Key #04 Partition Assignment,Partition 1
> Wireless Key #05 Partition Assignment,Partition 1
> Wireless Key #06 Partition Assignment,Partition 1
> Wireless Key #07 Partition Assignment,Partition 1
> Wireless Key #08 Partition Assignment,Partition 1
> Wireless Key #09 Partition Assignment,Partition 1
> Wireless Key #10 Partition Assignment,Partition 1
> Wireless Key #11 Partition Assignment,Partition 1
> Wireless Key #12 Partition Assignment,Partition 1
> Wireless Key #13 Partition Assignment,Partition 1
> Wireless Key #14 Partition Assignment,Partition 1
> Wireless Key #15 Partition Assignment,Partition 1
> Wireless Key #16 Partition Assignment,Partition 1
>
> $Table=PGM Output 1 Option [70]
> PGM Output 1 Option,Main Panel PGM 1
>
> $Table=PGM Output 2 Option [71]
> PGM Output 2 Option,Main Panel PGM 2
>
> $Table=PGM 1 Activation Time [72]
> PGM 1 Output Activation Time,00,05,MM:SS
>
> $Table=PGM 2 Activation Time [73]
> PGM 2 Output Activation Time,00,05,MM:SS
>
> $Table=Wireless Supervisory Window [81]
> RF Transmitter Supervisory Window,16
>
> $Table=Zone Transmitter Supervision Options 1 to 8 [82]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,Zone 01 Supervision Enabled,Zone 01 Supervision Disabled
> Disabled,2,Zone 02 Supervision Enabled,Zone 02 Supervision Disabled
> Disabled,3,Zone 03 Supervision Enabled,Zone 03 Supervision Disabled
> Disabled,4,Zone 04 Supervision Enabled,Zone 04 Supervision Disabled
> Disabled,5,Zone 05 Supervision Enabled,Zone 05 Supervision Disabled
> Disabled,6,Zone 06 Supervision Enabled,Zone 06 Supervision Disabled
> Disabled,7,Zone 07 Supervision Enabled,Zone 07 Supervision Disabled
> Enabled,8,Zone 08 Supervision Enabled,Zone 08 Supervision Disabled
>
> $Table=Zone Transmitter Supervision Options 9 to 16 [83]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Zone 09 Supervision Enabled,Zone 09 Supervision Disabled
> Disabled,2,Zone 10 Supervision Enabled,Zone 10 Supervision Disabled
> Disabled,3,Zone 11 Supervision Enabled,Zone 11 Supervision Disabled
> Disabled,4,Zone 12 Supervision Enabled,Zone 12 Supervision Disabled
> Disabled,5,Zone 13 Supervision Enabled,Zone 13 Supervision Disabled
> Disabled,6,Zone 14 Supervision Enabled,Zone 14 Supervision Disabled
> Disabled,7,Zone 15 Supervision Enabled,Zone 15 Supervision Disabled
> Disabled,8,Zone 16 Supervision Enabled,Zone 16 Supervision Disabled
>
> $Table=Zone Transmitter Supervision Options 17 to 24 [84]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Zone 17 Supervision Enabled,Zone 17 Supervision Disabled
> Disabled,2,Zone 18 Supervision Enabled,Zone 18 Supervision Disabled
> Disabled,3,Zone 19 Supervision Enabled,Zone 19 Supervision Disabled
> Disabled,4,Zone 20 Supervision Enabled,Zone 20 Supervision Disabled
> Disabled,5,Zone 21 Supervision Enabled,Zone 21 Supervision Disabled
> Disabled,6,Zone 22 Supervision Enabled,Zone 22 Supervision Disabled
> Disabled,7,Zone 23 Supervision Enabled,Zone 23 Supervision Disabled
> Disabled,8,Zone 24 Supervision Enabled,Zone 24 Supervision Disabled
>
> $Table=Zone Transmitter Supervision Options 25 to 32 [85]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Zone 25 Supervision Enabled,Zone 25 Supervision Disabled
> Disabled,2,Zone 26 Supervision Enabled,Zone 26 Supervision Disabled
> Disabled,3,Zone 27 Supervision Enabled,Zone 27 Supervision Disabled
> Disabled,4,Zone 28 Supervision Enabled,Zone 28 Supervision Disabled
> Disabled,5,Zone 29 Supervision Enabled,Zone 29 Supervision Disabled
> Disabled,6,Zone 30 Supervision Enabled,Zone 30 Supervision Disabled
> Disabled,7,Zone 31 Supervision Enabled,Zone 31 Supervision Disabled
> Disabled,8,Zone 32 Supervision Enabled,Zone 32 Supervision Disabled
>
> $Table=General Options [90]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,For Future Use
> Disabled,2,For Future Use
> Disabled,3,For Future Use
> Disabled,4,For Future Use
> Disabled,5,For Future Use
> Enabled,6,Keypad Zone Enable,PGM 2 Output Enable
> Enabled,7,RF Jam Doesn't Initiate Trouble,RF Jam Initiates Trouble
> Disabled,8,Global Placement Test,Individual Placement Test
>
> $Table=RF Jam Detect Zone [93]
> RF Jam Detect Zone,00,Valid Entries 1-32 (00 Jam Detect Disabled)
>
> $File=C:\DLS\Folders\ramos\kljkl.dsc
> $File_id=PC1555MX/Version 2.3
> $Date=5:13:47 PM 8/5/2006
> Customer Information
> Company,
> Contact,
> Department,
> Extension,
> Address,
> City,
> Province/State,
> Postal/Zip Code,
> Voice Telephone Number,
> Email Address,
> Panel Telephone Number:, 9999999999
> Additional Comments,
>
> $Table=User Access Codes
> Access Code,Code,Enabled,Bypass,Bell,Escort,Comments,*
> Code 01,AAAA,No,No,No,No,
> Code 02,AAAA,No,No,No,No,
> Code 03,AAAA,No,No,No,No,
> Code 04,AAAA,No,No,No,No,
> Code 05,AAAA,No,No,No,No,
> Code 06,AAAA,No,No,No,No,
> Code 07,AAAA,No,No,No,No,
> Code 08,AAAA,No,No,No,No,
> Code 09,AAAA,No,No,No,No,
> Code 10,AAAA,No,No,No,No,
> Code 11,AAAA,No,No,No,No,
> Code 12,AAAA,No,No,No,No,
> Code 13,AAAA,No,No,No,No,
> Code 14,AAAA,No,No,No,No,
> Code 15,AAAA,No,No,No,No,
> Code 16,AAAA,No,No,No,No,
> Code 17,AAAA,No,No,No,No,
> Code 18,AAAA,No,No,No,No,
> Code 19,AAAA,No,No,No,No,
> Code 20,AAAA,No,No,No,No,
> Code 21,AAAA,No,No,No,No,
> Code 22,AAAA,No,No,No,No,
> Code 23,AAAA,No,No,No,No,
> Code 24,AAAA,No,No,No,No,
> Code 25,AAAA,No,No,No,No,
> Code 26,AAAA,No,No,No,No,
> Code 27,AAAA,No,No,No,No,
> Code 28,AAAA,No,No,No,No,
> Code 29,AAAA,No,No,No,No,
> Code 30,AAAA,No,No,No,No,
> Code 31,AAAA,No,No,No,No,
> Code 32,AAAA,No,No,No,No,
> Duress Code 33,AAAA,No,No,No,No,
> Duress Code 34,AAAA,No,No,No,No,
> System Master ,4337,Yes,Yes,No,Yes,
> Supervisor Code 41,AAAA,No,No,No,No,
> Supervisor Code 42,AAAA,No,No,No,No,
>
> $Table=Zone 1 to 8 Definitions [001]
> Zone,Definition,Comments
> Zone 01,(03) Instant,
> Zone 02,(00) Null Zone (Not Used),
> Zone 03,(00) Null Zone (Not Used),
> Zone 04,(00) Null Zone (Not Used),
> Zone 05,(00) Null Zone (Not Used),
> Zone 06,(00) Null Zone (Not Used),
> Zone 07,(00) Null Zone (Not Used),
> Zone 08,(00) Null Zone (Not Used),
>
> $Table=Zone 9 to 16 Definitions [002]
> Zone,Definition,Comments
> Zone 09,(00) Null Zone (Not Used),
> Zone 10,(00) Null Zone (Not Used),
> Zone 11,(00) Null Zone (Not Used),
> Zone 12,(00) Null Zone (Not Used),
> Zone 13,(00) Null Zone (Not Used),
> Zone 14,(00) Null Zone (Not Used),
> Zone 15,(00) Null Zone (Not Used),
> Zone 16,(00) Null Zone (Not Used),
>
> $Table=Zone 17 to 24 Definitions [003]
> Zone,Definition,Comments
> Zone 17,(00) Null Zone (Not Used),
> Zone 18,(00) Null Zone (Not Used),
> Zone 19,(00) Null Zone (Not Used),
> Zone 20,(00) Null Zone (Not Used),
> Zone 21,(00) Null Zone (Not Used),
> Zone 22,(00) Null Zone (Not Used),
> Zone 23,(00) Null Zone (Not Used),
> Zone 24,(00) Null Zone (Not Used),
>
> $Table=Zone 25 to 32 Definitions [004]
> Zone,Definition,Comments
> Zone 25,(00) Null Zone (Not Used),
> Zone 26,(00) Null Zone (Not Used),
> Zone 27,(00) Null Zone (Not Used),
> Zone 28,(00) Null Zone (Not Used),
> Zone 29,(00) Null Zone (Not Used),
> Zone 30,(00) Null Zone (Not Used),
> Zone 31,(00) Null Zone (Not Used),
> Zone 32,(00) Null Zone (Not Used),
>
> $Table=System Times [005]
> Entry Delay 1,030,Seconds
> Entry Delay 2,045,Seconds
> Exit Delay,120,Seconds
> Bell Cut-Off,004,Minutes
>
> $Table=Auto Arm Time
> System,9999,Valid entries are 0000-2359, 9999 to Disable
>
> $Table=Installer's Code [006]
> Installer's Code,4337
>
> $Table=Master Code [007]
> Master Code,4337
>
> $Table=Maintenance Code [008]
> Maintenance Code,AAAA,Enter Decimal Data (AAAA or AAAA00 to disable)
>
> $Table=PC1555MX PGM's 1 & 2 (Onboard) [009]
> Attributes,Definition
> PGM 01,(19) (*71) Command Output #1
> PGM 02,(10) System Event
>
> $Table=PC5208 PGM's 3 to 10 [010]
> Attributes,Definition
> PGM 03,(01) Fire and Burglary Bell Output
> PGM 04,(01) Fire and Burglary Bell Output
> PGM 05,(01) Fire and Burglary Bell Output
> PGM 06,(01) Fire and Burglary Bell Output
> PGM 07,(01) Fire and Burglary Bell Output
> PGM 08,(01) Fire and Burglary Bell Output
> PGM 09,(01) Fire and Burglary Bell Output
> PGM 10,(01) Fire and Burglary Bell Output
>
> $Table=PC5204 PGM's 11 to 14 [011]
> Attributes,Definition
> PGM 11,(01) Fire and Burglary Bell Output
> PGM 12,(01) Fire and Burglary Bell Output
> PGM 13,(01) Fire and Burglary Bell Output
> PGM 14,(01) Fire and Burglary Bell Output
>
> $Table=Keypad Lockout Options [012]
> Number Invalid Codes Before Lockout,000,000-255 Invalid Codes
> Lockout Duration,000,000-255 Minutes
>
> $Table=First System Option Code [013]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Normally Closed Loops,End-Of-Line Resistors
> Disabled,2,Double End-Of-Line Resistors,Single End-Of-Line Resistors
> Enabled,3,Panel Shows All Troubles While Armed,Panel Shows Only Fire
> Troubles While Armed
> Disabled,4,Tampers/Faults Do Not Show As Open,Tampers/Faults Show As
> Open
> Disabled,5,For Future Use
> Enabled,6,Audible Exit Fault Enabled,Audible Exit Fault Disabled
> Enabled,7,Event Buffer Follows Swinger Shutdown,Event Buffer Logs
> Events Past Shutdown
> Disabled,8,Temporal Three Fire Signal Enabled,Standard Pulsed Fire
> Signal
>
> $Table=Second System Option Code [014]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Arm/Disarm Bell Squawk Enabled,Arm/Disarm Bell Squawk
> Disabled
> Disabled,2,Bell Squawk During Auto Arm,No Bell Squawk During Auto Arm
> Disabled,3,Bell Squawk On Exit Delay,No Bell Squawk On Exit Delay
> Disabled,4,Bell Squawk On Entry Delay,No Bell Squawk On Entry Delay
> Disabled,5,Bell Squawk On Trouble,No Bell Squawk On Trouble
> Enabled,6,Audible Exit Beeps,Silent Exit Delay
> Disabled,7,Exit Delay Termination Enabled,Exit Delay Termination
> Disabled
> Disabled,8,Fire Bell Is Continuous,Fire Bell Follows Bell Cut-off
>
> $Table=Third System Option Code [015]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,[F] Key Enabled,[F] Key Disabled
> Disabled,2,[P] Key Audible (Bell/Beeps),[P] Key Silent
> Disabled,3,Quick Exit Enabled,Quick Exit Disabled
> Enabled,4,Quick Arming Enabled,Quick Arming Disabled (Funct. Keys Req.
> Code)
> Disabled,5,Code Required For Bypassing,No Code Required
> Disabled,6,Master Code Not Changeable,Master Code Changeable
> Disabled,7,TLM Enabled,TLM Disabled
> Disabled,8,TLM Audible When Armed,TLM Trouble Only When Armed
>
> $Table=Fourth System Option Code [016]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,AC Trouble Displayed,AC Trouble Not Displayed
> Disabled,2,Trouble Light Flashes if AC Fails,Trouble Light Does Not
> Follow AC Status
> Disabled,3,Blank Keypad When Not Used,Keypad Active Always
> Disabled,4,Code Required to Remove Keypad Blanking,No Code Required
> Enabled,5,Keypad Backlighting is Enabled,Keypad Backlighting is
> Disabled
> Disabled,6,Power Save Mode Enabled,Power Save Mode Disabled
> Disabled,7,Bypass Status Displayed While Armed,Bypass Status Not
> Displayed While Armed
> Disabled,8,Keypad Tampers Enabled,Keypad Tampers Disabled
>
> $Table=Fifth System Option Code [017]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,WLSKEY Does Not Use Access Codes,WLSKEY Uses Access Codes
> Disabled,2,For Future Use
> Disabled,3,For Future Use
> Disabled,4,For Future Use
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,Squawk on Away Arming/Disarming Only,Bell Squawk on all
> Arming/Disarming
>
> $Table=Keypad Zone Assignments [020]
> Keypad 1 Zone,00
> Keypad 2 Zone,00
> Keypad 3 Zone,00
> Keypad 4 Zone,00
> Keypad 5 Zone,00
> Keypad 6 Zone,00
> Keypad 7 Zone,00
> Keypad 8 Zone,00
>
> $Table=Zone Loop Response Option Code [030]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Zone 1 is Fast Response,Zone 1 is Normal Loop Response
> Disabled,2,Zone 2 is Fast Response,Zone 2 is Normal Loop Response
> Disabled,3,Zone 3 is Fast Response,Zone 3 is Normal Loop Response
> Disabled,4,Zone 4 is Fast Response,Zone 4 is Normal Loop Response
> Disabled,5,Zone 5 is Fast Response,Zone 5 is Normal Loop Response
> Disabled,6,Zone 6 is Fast Response,Zone 6 is Normal Loop Response
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=Zone 1 to 8 Attributes [101]...[108]
> Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
> Zone 01,Yes,Yes,Yes,Yes,No,Yes,No,Yes,(03) Instant
> Zone 02,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 03,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 04,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 05,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 06,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 07,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 08,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
>
> $Table=Zone 9 to 16 Attributes [109]...[116]
> Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
> Zone 09,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 10,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 11,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 12,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 13,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 14,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 15,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 16,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
>
> $Table=Zone 17 to 24 Attributes [117]...[124]
> Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
> Zone 17,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 18,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 19,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 20,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 21,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 22,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 23,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 24,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
>
> $Table=Zone 25 to 32 Attributes [125]...[132]
> Zone,Audible,Steady,Chime,Bypass,Force,Swinger,Tx Del,Wls,Definition
> Zone 25,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 26,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 27,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 28,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 29,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 30,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 31,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 32,No,No,No,No,No,No,No,No,(00) Null Zone (Not Used)
>
> $Table=PC1555MX PGM 1 Attributes [141]
> Output,En,N\A,True,Pul,Code,N\A,N\A,N\A
> PGM 01,Yes,No,Yes,Yes,Yes,No,No,No,(19) (*71) Command Output #1
>
> $Table=PC1555MX PGM 2 Attributes [142]
> Output,Burg.,Fire,Panic,Med.,Supv.,Priority,Hldup,O/P Timer
> PGM 02,Yes,Yes,Yes,Yes,Yes,Yes,Yes,No,(10) System Event
>
> $Table=PC5208 PGM 3 Attributes [143]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 03,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 4 Attributes [144]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 04,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 5 Attributes [145]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 05,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 6 Attributes [146]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 06,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 7 Attributes [147]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 07,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 8 Attributes [148]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 08,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 9 Attributes [149]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 09,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5208 PGM 10 Attributes [150]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 10,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5204 PGM 11 Attributes [151]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 11,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5204 PGM 12 Attributes [152]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 12,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5204 PGM 13 Attributes [153]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 13,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=PC5204 PGM 14 Attributes [154]
> Output,En,N\A,True,N\A,N\A,N\A,N\A,N\A
> PGM 14,Yes,No,Yes,No,No,No,No,No,(01) Fire and Burglary Bell Output
>
> $Table=Maximum Dialing Attempts [160]
> 008,Valid entries are 001-255 attempts
>
> $Table=Post Dial Wait for Handshake [161]
> 040,Valid entries are 001-255 seconds
>
> $Table=PGM Output Timer [164]
> 005,Valid Entries are 001-255 seconds
>
> $Table=Zone Assignments (Zones 1-8) [202]
> Zone,Setting,Option,Option Enabled,Option Disabled
> Zone 01,Enabled,1,Zone 1 is Enabled,Zone 1 is Disabled
> Zone 02,Disabled,2,Zone 2 is Enabled,Zone 2 is Disabled
> Zone 03,Disabled,3,Zone 3 is Enabled,Zone 3 is Disabled
> Zone 04,Disabled,4,Zone 4 is Enabled,Zone 4 is Disabled
> Zone 05,Disabled,5,Zone 5 is Enabled,Zone 5 is Disabled
> Zone 06,Disabled,6,Zone 6 is Enabled,Zone 6 is Disabled
> Zone 07,Disabled,7,Zone 7 is Enabled,Zone 7 is Disabled
> Zone 08,Disabled,8,Zone 8 is Enabled,Zone 8 is Disabled
>
> $Table=Zone Assignments (Zones 9-16) [203]
> Zone,Setting,Option,Option Enabled,Option Disabled
> Zone 09,Disabled,1,Zone 09 is Enabled,Zone 09 is Disabled
> Zone 10,Disabled,2,Zone 10 is Enabled,Zone 10 is Disabled
> Zone 11,Disabled,3,Zone 11 is Enabled,Zone 11 is Disabled
> Zone 12,Disabled,4,Zone 12 is Enabled,Zone 12 is Disabled
> Zone 13,Disabled,5,Zone 13 is Enabled,Zone 13 is Disabled
> Zone 14,Disabled,6,Zone 14 is Enabled,Zone 14 is Disabled
> Zone 15,Disabled,7,Zone 15 is Enabled,Zone 15 is Disabled
> Zone 16,Disabled,8,Zone 16 is Enabled,Zone 16 is Disabled
>
> $Table=Zone Assignments (Zones 17-24) [204]
> Zone,Setting,Option,Option Enabled,Option Disabled
> Zone 17,Disabled,1,Zone 17 is Enabled,Zone 17 is Disabled
> Zone 18,Disabled,2,Zone 18 is Enabled,Zone 18 is Disabled
> Zone 19,Disabled,3,Zone 19 is Enabled,Zone 19 is Disabled
> Zone 20,Disabled,4,Zone 20 is Enabled,Zone 20 is Disabled
> Zone 21,Disabled,5,Zone 21 is Enabled,Zone 21 is Disabled
> Zone 22,Disabled,6,Zone 22 is Enabled,Zone 22 is Disabled
> Zone 23,Disabled,7,Zone 23 is Enabled,Zone 23 is Disabled
> Zone 24,Disabled,8,Zone 24 is Enabled,Zone 24 is Disabled
>
> $Table=Zone Assignments (Zones 25-32) [205]
> Zone,Setting,Option,Option Enabled,Option Disabled
> Zone 25,Disabled,1,Zone 25 is Enabled,Zone 25 is Disabled
> Zone 26,Disabled,2,Zone 26 is Enabled,Zone 26 is Disabled
> Zone 27,Disabled,3,Zone 27 is Enabled,Zone 27 is Disabled
> Zone 28,Disabled,4,Zone 28 is Enabled,Zone 28 is Disabled
> Zone 29,Disabled,5,Zone 29 is Enabled,Zone 29 is Disabled
> Zone 30,Disabled,6,Zone 30 is Enabled,Zone 30 is Disabled
> Zone 31,Disabled,7,Zone 31 is Enabled,Zone 31 is Disabled
> Zone 32,Disabled,8,Zone 32 is Enabled,Zone 32 is Disabled
>
> $Table=Communicator Telephone Numbers [301]...[303]
> Phone #,Enter Telephone # (32 Digits max.)
> First,D3783546FFFFFFFFFFFFFFFFFFFFFFFF
> Second,FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
> Third,FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
>
> $Table=Account Codes [310]...[311]
> Telephone #,Identifier Code
> Telephone #1/3 Account Code,4337
> Telephone #2 Account Code,FFFF
>
> $Table=Alarm Reporting Codes, Zones 1 to 8 [320]
> Zone,Code,Zone,Code
> Zone 01,FF,Zone 05,FF
> Zone 02,FF,Zone 06,FF
> Zone 03,FF,Zone 07,FF
> Zone 04,FF,Zone 08,FF
>
> $Table=Alarm Reporting Codes, Zones 9 to 16 [321]
> Zone,Code,Zone,Code
> Zone 09,FF,Zone 13,FF
> Zone 10,FF,Zone 14,FF
> Zone 11,FF,Zone 15,FF
> Zone 12,FF,Zone 16,FF
>
> $Table=Alarm Reporting Codes, Zones 17 to 24 [322]
> Zone,Code,Zone,Code
> Zone 17,FF,Zone 21,FF
> Zone 18,FF,Zone 22,FF
> Zone 19,FF,Zone 23,FF
> Zone 20,FF,Zone 24,FF
>
> $Table=Alarm Reporting Codes, Zones 25 to 32 [323]
> Zone,Code,Zone,Code
> Zone 25,FF,Zone 29,FF
> Zone 26,FF,Zone 30,FF
> Zone 27,FF,Zone 31,FF
> Zone 28,FF,Zone 32,FF
>
> $Table=Alarm Restoral Reporting Codes, Zones 1 to 8 [324]
> Zone,Code,Zone,Code
> Zone 01,FF,Zone 05,FF
> Zone 02,FF,Zone 06,FF
> Zone 03,FF,Zone 07,FF
> Zone 04,FF,Zone 08,FF
>
> $Table=Alarm Restoral Reporting Codes, Zones 9 to 16 [325]
> Zone,Code,Zone,Code
> Zone 09,FF,Zone 13,FF
> Zone 10,FF,Zone 14,FF
> Zone 11,FF,Zone 15,FF
> Zone 12,FF,Zone 16,FF
>
> $Table=Alarm Restoral Reporting Codes, Zones 17 to 24 [326]
> Zone,Code,Zone,Code
> Zone 17,FF,Zone 21,FF
> Zone 18,FF,Zone 22,FF
> Zone 19,FF,Zone 23,FF
> Zone 20,FF,Zone 24,FF
>
> $Table=Alarm Restoral Reporting Codes, Zones 25 to 32 [327]
> Zone,Code,Zone,Code
> Zone 25,FF,Zone 29,FF
> Zone 26,FF,Zone 30,FF
> Zone 27,FF,Zone 31,FF
> Zone 28,FF,Zone 32,FF
>
> $Table=Miscellaneous Alarm Reporting Codes [328]
> Duress Alarm,FF,Zone Expander Supervisory Alarm,FF
> Opening After Alarm,FF,Zone Expander Supervisory Restoral,FF
> Recent Closing,FF,Cross Zone Police Code Alarm,FF
>
> $Table=Priority Alarm and Restoral Reporting Codes [329]
> Keypad [F]ire Alarm,FF,Keypad [F]ire Restoral,FF
> Keypad [A]uxiliary Alarm,FF,Keypad [A]uxiliary Restoral,FF
> Keypad [P]anic Alarm,FF,Keypad [P]anic Restoral,FF
> PGM 2 Alarm,FF,PGM 2 Restoral,FF
>
> $Table=Tamper Reporting Codes, Zones 1 to 8 [330]
> Zone,Code,Zone,Code
> Zone 01,FF,Zone 05,FF
> Zone 02,FF,Zone 06,FF
> Zone 03,FF,Zone 07,FF
> Zone 04,FF,Zone 08,FF
>
> $Table=Tamper Reporting Codes, Zones 9 to 16 [331]
> Zone,Code,Zone,Code
> Zone 09,FF,Zone 13,FF
> Zone 10,FF,Zone 14,FF
> Zone 11,FF,Zone 15,FF
> Zone 12,FF,Zone 16,FF
>
> $Table=Tamper Reporting Codes, Zones 17 to 24 [332]
> Zone,Code,Zone,Code
> Zone 17,FF,Zone 21,FF
> Zone 18,FF,Zone 22,FF
> Zone 19,FF,Zone 23,FF
> Zone 20,FF,Zone 24,FF
>
> $Table=Tamper Reporting Codes, Zones 25 to 32 [333]
> Zone,Code,Zone,Code
> Zone 25,FF,Zone 29,FF
> Zone 26,FF,Zone 30,FF
> Zone 27,FF,Zone 31,FF
> Zone 28,FF,Zone 32,FF
>
> $Table=Tamper Restoral Reporting Codes, Zones 1 to 8 [334]
> Zone,Code,Zone,Code
> Zone 01,FF,Zone 05,FF
> Zone 02,FF,Zone 06,FF
> Zone 03,FF,Zone 07,FF
> Zone 04,FF,Zone 08,FF
>
> $Table=Tamper Restoral Reporting Codes, Zones 9 to 16 [335]
> Zone,Code,Zone,Code
> Zone 09,FF,Zone 13,FF
> Zone 10,FF,Zone 14,FF
> Zone 11,FF,Zone 15,FF
> Zone 12,FF,Zone 16,FF
>
> $Table=Tamper Restoral Reporting Codes, Zones 17 to 24 [336]
> Zone,Code,Zone,Code
> Zone 17,FF,Zone 21,FF
> Zone 18,FF,Zone 22,FF
> Zone 19,FF,Zone 23,FF
> Zone 20,FF,Zone 24,FF
>
> $Table=Tamper Restoral Reporting Codes, Zones 25 to 32 [337]
> Zone,Code,Zone,Code
> Zone 25,FF,Zone 29,FF
> Zone 26,FF,Zone 30,FF
> Zone 27,FF,Zone 31,FF
> Zone 28,FF,Zone 32,FF
>
> $Table=Miscellaneous Tamper Reporting Codes [338]
> General System Tamper,FF
> General System Tamper Restoral,FF
> Keypad Lockout,FF
>
> $Table=Closing (Arming) Reporting Codes, Access Codes 1 to 8 [339]
> Access Code 01,FF,Access Code 05,FF
> Access Code 02,FF,Access Code 06,FF
> Access Code 03,FF,Access Code 07,FF
> Access Code 04,FF,Access Code 08,FF
>
> $Table=Closing (Arming) Reporting Codes, Access Codes 9 to 16 [340]
> Access Code 09,FF,Access Code 13,FF
> Access Code 10,FF,Access Code 14,FF
> Access Code 11,FF,Access Code 15,FF
> Access Code 12,FF,Access Code 16,FF
>
> $Table=Closing (Arming) Reporting Codes, Access Codes 17 to 24 [341]
> Access Code 17,FF,Access Code 21,FF
> Access Code 18,FF,Access Code 22,FF
> Access Code 19,FF,Access Code 23,FF
> Access Code 20,FF,Access Code 24,FF
>
> $Table=Closing (Arming) Reporting Codes, Access Codes 25 to 32 [342]
> Access Code 25,FF,Access Code 29,FF
> Access Code 26,FF,Access Code 30,FF
> Access Code 27,FF,Access Code 31,FF
> Access Code 28,FF,Access Code 32,FF
>
> $Table=Miscellaneous Closing (Arming) Reporting Codes [343]
> Duress Code 33,FF,Supervisor Code 42,FF
> Duress Code 34,FF,Partial Closing,FF
> System Master,FF,Special Closing,FF
> Supervisor Code 41,FF
>
> $Table=Opening (Disarming) Reporting Codes, Access Codes 1 to 8 [344]
> Access Code 01,FF,Access Code 05,FF
> Access Code 02,FF,Access Code 06,FF
> Access Code 03,FF,Access Code 07,FF
> Access Code 04,FF,Access Code 08,FF
>
> $Table=Opening (Disarming) Reporting Codes, Access Codes 9 to 16 [345]
> Access Code 09,FF,Access Code 13,FF
> Access Code 10,FF,Access Code 14,FF
> Access Code 11,FF,Access Code 15,FF
> Access Code 12,FF,Access Code 16,FF
>
> $Table=Opening (Disarming) Reporting Codes, Access Codes 17 to 24 [346]
> Access Code 17,FF,Access Code 21,FF
> Access Code 18,FF,Access Code 22,FF
> Access Code 19,FF,Access Code 23,FF
> Access Code 20,FF,Access Code 24,FF
>
> $Table=Opening (Disarming) Reporting Codes, Access Codes 25 to 32 [347]
> Access Code 25,FF,Access Code 29,FF
> Access Code 26,FF,Access Code 30,FF
> Access Code 27,FF,Access Code 31,FF
> Access Code 28,FF,Access Code 32,FF
>
> $Table=Miscellaneous Opening (Disarming) Reporting Codes [348]
> Duress Code 33,FF,Supervisor Code 42,FF
> Duress Code 34,FF,Auto-Arm Cancellation,FF
> System Master,FF,Special Opening,FF
> Supervisor Code 41,FF
>
> $Table=Maintenance Alarm Reporting Codes [349]
> Battery Trouble Alarm,FF
> AC Failure Trouble Alarm,FF
> Bell Circuit Trouble Alarm,FF
> Fire Trouble Alarm,FF
> Auxiliary Power Supply Trouble Alarm,FF
> TLM Trouble Code (via LINKS),FF
> General System Trouble,FF
> General System Supervisory,FF
>
> $Table=Maintenance Restoral Reporting Codes [350]
> Battery Trouble Restoral,FF
> AC Failure Trouble Restoral,FF
> Bell Circuit Trouble Restoral,FF
> Fire Trouble Restoral,FF
> Auxiliary Power Supply Trouble Restoral,FF
> TLM Restoral,FF
> General System Trouble Restoral,FF
> General System Supervisory Restoral,FF
>
> $Table=Miscellaneous Maintenance Reporting Codes [351]
> Phone Number 1 Failure to Communicate,FF
> Phone Number 2 Failure to Communicate,FF
> Event Buffer is 75% Full Since Last Upload,FF
> DLS Lead IN,FF
> DLS Lead OUT,FF
> General Zone Trouble Alarm,FF
> General Zone Trouble Restoral,FF
> Delinquency,FF
>
> $Table=Test Transmission Reporting Codes [352]
> Periodic Test Transmission,FF
> System Test,FF
> LINKS 1000 Test Transmission Code,FF
>
> $Table=Wireless Maintenance Reporting Codes [353]
> General Zone Low Battery Alarm,FF
> General Zone Low Battery Restore,FF
>
> $Table=Communicator Format Options [360]
> First and Third Phone Number,(02) 20 BPS, 2300Hz Handshake
> Second Phone Number,(02) 20 BPS, 2300Hz Handshake
>
> $Table=Alarms & Restorals [361]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,First Telephone Number,Disabled
> Disabled,2,Second Telephone Number,Disabled
> Disabled,3,First Telephone Number (via LINKS),Disabled
> Disabled,4,Second Telephone Number (via LINKS),Disabled
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=Tampers & Restorals [363]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,First Telephone Number,Disabled
> Disabled,2,Second Telephone Number,Disabled
> Disabled,3,First Telephone Number (via LINKS),Disabled
> Disabled,4,Second Telephone Number (via LINKS),Disabled
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=Openings & Closings [365]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,First Telephone Number,Disabled
> Disabled,2,Second Telephone Number,Disabled
> Disabled,3,First Telephone Number (via LINKS),Disabled
> Disabled,4,Second Telephone Number (via LINKS),Disabled
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=System Maintenance Alarms & Restorals [367]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,First Telephone Number,Disabled
> Disabled,2,Second Telephone Number,Disabled
> Disabled,3,First Telephone Number (via LINKS),Disabled
> Disabled,4,Second Telephone Number (via LINKS),Disabled
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=System Test Transmissions [368]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,First Telephone Number,Disabled
> Disabled,2,Second Telephone Number,Disabled
> Disabled,3,First Telephone Number (via LINKS),Disabled
> Disabled,4,Second Telephone Number (via LINKS),Disabled
> Disabled,5,For Future Use
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=Communication Variables [370]
> 003,Swinger Shutdown (Alarms & Restorals),(000-255 Transmissions,
> 000=Disabled)
> 003,Swinger Shutdown (Tampers & Restorals),(000-255 Transmissions,
> 000=Disabled)
> 003,Swinger Shutdown (Maint. & Restorals),(000-255 Transmissions,
> 000=Disabled)
> 000,Communication Delay,(000-255 Seconds)
> 030,AC Failure Communication Delay,(001-255 minutes, 000=disabled)
> 003,TLM Trouble Delay,Number of valid checks required +3...000-255 x
> 10s
> 030,Test Transmission Cycle (land-line),(000-255 Days/Minutes)
> 030,LINKS Test Transmission Cycle,(000-255 Days)
> 007,Zone Low Battery Transmission Delay,(000-255 Days)
> 030,Delinquency Timer,(000-255 Days/Hours)
>
> $Table=Test Transmission Time Of Day [371]
> 9999,Valid entries are 0000-2359, 9999 to Disable
>
> $Table=First Communicator Option Code [380]
> Setting,Option,Option Enabled,Option Disabled
> Enabled,1,Communications Enabled,Communications Disabled
> Disabled,2,Restorals On Bell Time Out,Restorals Follow Zones
> Disabled,3,Pulse Dialing,DTMF Dialing
> Enabled,4,Switch to Pulse Dialing On 5th Attempt,DTMF Dial For All
> Attempts
> Disabled,5,3rd Phone Number Enabled,3rd Phone Number Disabled
> Disabled,6,Alternate Dial (First & 3rd),Call First Number, Backup to
> 3rd
> Disabled,7,Call LINKS as well as Land Line,LINKS is Backup of Land
> Line(s)
> Disabled,8,Delinquency Follows Zone Activity (Hours),Delinquency
> Follows Arming (Days)
>
> $Table=Second Communicator Option Code [381]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Opening After Alarm Keypad Ringback Enabled,Opening After
> Alarm Keypad Ringback Disabled
> Disabled,2,Opening After Alarm Bell Ringback Enabled,Opening After
> Alarm Bell Ringback Disabled
> Disabled,3,SIA Sends Programmed Reporting Codes,SIA Sends Automatic
> Reporting Codes
> Disabled,4,Closing Confirmation Enabled,Closing Confirmation Disabled
> Enabled,5,Talk/Listen (PC5928) on Phone #1/3 Enabled,Talk/Listen
> (PC5928) on Phone #1/3 Disabled
> Disabled,6,Phone 2 Listen In Enabled,Phone 2 Listen In Disabled
> Enabled,7,Contact I.D. Uses Pgm'd Rep. Codes,Contact I.D. Uses Auto
> Rep. Codes
> Disabled,8,For Future Use
>
> $Table=LINKS Preambles [390]...[393]
> First Preamble (First Telephone Number),FFFF
> Second Preamble (Second Telephone Number),FFFF
> Third Preamble (Third Telephone Number),FFFF
> Special Function Preamble (All Numbers),FFFFFF
>
> $Table=First Downloading Option Code [401]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Downloading Answer Enabled,Downloading Answer Disabled
> Enabled,2,User Can Enable DLS Window,User Can Not Enable DLS Window
> Disabled,3,Call-Back Enabled,Call-Back Disabled
> Disabled,4,User Initiated Call Up Enabled,User Initiated Call Up
> Disabled
> Disabled,5,Auto Event Buffer Upload Enabled,Auto Event Buffer Upload
> Disabled
> Disabled,6,For Future Use
> Disabled,7,For Future Use
> Disabled,8,For Future Use
>
> $Table=Downloading Computer's Telephone Number [402]
> FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF,(32 Digits max.)
>
> $Table=Downloading Access Code [403]
> 4337,Enter 4 Hexadecimal Digits
>
> $Table=Panel Identification Code [404]
> 5008,Enter 4 Hexadecimal Digits
>
> $Table=Answering Machine Double-Call Timer [405]
> 060,Valid entries are 001-255 Seconds
>
> $Table=Number of Rings [406]
> 000,Valid entries are 000-255 Rings
>
> $Table=LINKS Preamble (Downloading Phone Number) [490]
> FFFF,All unused digits are programmed with Hex F
>
> $Table=Automatic Clock Adjust [700]
> 60,Valid entries are 00-99 Seconds
>
> $Table=First International Options Code [701]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,50 Hz AC,60 Hz AC
> Disabled,2,Time Base is Internal Crystal,Time Base is AC Line
> Disabled,3,AC/DC Arming Inhibit Enabled,AC/DC Arming Inhibit Disabled
> Disabled,4,All System Tampers Require Installer Reset,All System
> Tampers follow Restore
> Disabled,5,6-Digit User Access Codes,4-Digit User Access Codes
> Disabled,6,Busy Tone Detection Enabled,Busy Tone Detection Disabled
> Disabled,7,High Current Battery Charge,Standard Current Battery Charge
> Disabled,8,For Future Use
>
> $Table=Second International Options Code [702]
> Setting,Option,Option Enabled,Option Disabled
> Disabled,1,Pulse Dialing Make/Break Ratio is 33/67,Pulse Dialing
> Make/Break Ratio is 40/60
> Enabled,2,Force Dialing Enabled,Force Dialing Disabled
> Disabled,3,Test Transmission Interval in Minutes,Test Transmission
> Interval in Days
> Disabled,4,1600 Hz Handshake,Standard Handshake
> Disabled,5,ID Tone Enabled,ID Tone Disabled
> Disabled,6,2100 Hz ID Tone,1300 Hz ID Tone
> Disabled,7,One Time 1-Hr User Enabled DLS Window,Full 6-Hr User Enabled
> DLS Window
> Disabled,8,Bell Enabled FTC when Armed,FTC Trouble only when Armed
>
> $Table=Delay Between Dialing Attempts [703]
> 001,Valid entries are 000-255 Seconds
>
> $Table=Zone Status
> Zone,Mem,Open,Fault,Tmpr,LoBat,Bypass,Definition
> Zone 01,No,No,No,No,No,No,(03) Instant
> Zone 02,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 03,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 04,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 05,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 06,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 07,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 08,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 09,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 10,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 11,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 12,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 13,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 14,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 15,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 16,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 17,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 18,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 19,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 20,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 21,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 22,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 23,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 24,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 25,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 26,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 27,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 28,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 29,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 30,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 31,No,No,No,No,No,No,(00) Null Zone (Not Used)
> Zone 32,No,No,No,No,No,No,(00) Null Zone (Not Used)
>
> $Table=Arm Status
> System,Disarmed
>
> $Table=Door Chime Status
> System,Disable
>
> $Table=Auto Arm Status
> System,Disable
>
> $Table=Time & Date
> Time,16,51,HH:MM
> Date,08,05,06,MM/DD/YY
>
> $Table=Trouble Status
> Low Battery,No,WKEY 01 Low Bat,No,HHK 1 Low Bat,No
> Bell Circuit Failure,No,WKEY 02 Low Bat,No,HHK 2 Low Bat,No
> General System Trouble,No,WKEY 03 Low Bat,No,HHK 3 Low Bat,No
> General System Tamper,No,WKEY 04 Low Bat,No,HHK 4 Low Bat,No
> General System Supervisory,No,WKEY 05 Low Bat,No
> 5204 Low Battery,No,WKEY 06 Low Bat,No
> 5204 AC Fail,No,WKEY 07 Low Bat,No
> AC Fail,No,WKEY 08 Low Bat,No
> TLM Trouble,No,WKEY 09 Low Bat,No
> Fail To Communicate,No,WKEY 10 Low Bat,No
> Zone Fault,No,WKEY 11 Low Bat,No
> Zone Tamper,No,WKEY 12 Low Bat,No
> Device Low Battery,No,WKEY 13 Low Bat,No
> Loss of Time,No,WKEY 14 Low Bat,No
> WKEY 15 Low Bat,No
> WKEY 16 Low Bat,No
>
> $Table=Module Supervisory
> Module,Enrolled,Trouble,Module,Enrolled,Trouble
> Keypad 1,Yes,No,Escort 5580,No,N/A
> Keypad 2,No,N/A, Alt. Comms,No,N/A
> Keypad 3,No,N/A,PC59XX,No,N/A
> Keypad 4,No,N/A,PC5400,No,N/A
> Keypad 5,No,N/A,PC5204,No,N/A
> Keypad 6,No,N/A,PC5208,No,N/A
> Keypad 7,No,N/A,PC5132,Yes,No
> Keypad 8,No,N/A
>
> $Table=Keypad Lockout Status
> System,No
>
> $Table=Installer Lockout Status
> System,Disable
>
>
>
>
>