Re: NX8E master user fault
Yo Spyros,
*8 is for installer level programming.
1234 is the Default Master User Code
*5 is for changing codes need Master User Code.
9713 is the Default Installer Code
They will not always intermix.
Do the following first. * 8 9 7 1 3 0 # 9 1 0 # {EXIT} {EXIT}
This will Default the panel.
Then to change master code * 5 1 2 3 4 0 0 1 (new master code)
# to exit
After that read the Installation Manual.
Good luck,
Les
> Recently i install a Caddx NX8E-GR. Everything was ok except the basic!
> The user #1 (master) does not have access to change his own code or to
> programm even other users. That means that in a brand new control
> panel, the user (#1 i believe) with code number 1234 by default isn't
> the master! The installtion area doesn't have (untill now) phone line
> so i cannot give master previledges by download via DL900.
> Does anyone has any idea?!?! I'm trying [*] [8] [1234] and the ready
> light did not flash....
>
> Thanks in advance
>
> Spyros Kintzonides
> Thessaloniki - Greece
>