[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: 100 Base T



If you're planning on using the spare pairs in the cat5e it's do-able
but make sure:

You won't be using giga bit ethernet on that run in the future as it
uses all 4 pairs.

Also POE (Power Over Ethernet) will use a pair as well if implemented.
(eg. powering a voip phone from the ethernet switch)

Both of these snaggles may not be in place now but future
users/designers must be made aware if you're planning on using pairs in
the cat5e in a non-standard way.


Crash Gordon wrote:

> Poifect!...thanks man.
>
>
> "Jim Rojas" <jrojas@xxxxxxxxxxxx> wrote in message
> news:Xa3Se.62$Sx4.1@xxxxxxxxxxx
>
>>http://www.arcelect.com/10baset.htm
>>
>>That will explain it all to you.
>>
>>Jim Rojas
>>
>>
>>"Crash Gordon" <webmaster@xxxxxxxxxxxxxxxxxxxxx> wrote in message
>>news:sZ2Se.382$1u4.7008@xxxxxxxxxxxxxxxxxx
>>
>>>Thats what I thought.
>>>Which ones (which colors)....I gotta do some cheating on new house
>>>prewired by idiots.
>>>


alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home