[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Multiple magnets, one zone, EOL resistor. Never works!



Well...what value resistor does whatever panel you are installing call for?
Ademco uses 1K or 2K, some other panels may have one value for a burg zone
and a DIFFERENT value for a fire zone.


"Total nerd" <geekboy0001@xxxxxxxxx> wrote in message
news:1130157128.212611.125660@xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
| Yeah, that's a good idea -- I simply shorted all the window contacts
| together and pulled the wires off the panel.  I measures 2.2K ohms on
| the meter.  Then, one at a time, I disconnected each window contact, to
| assure myself that it indeed produced an open circuit, and it did.  So
| either: you're right and the value of the resistor is not compatible
| with the panel, or the panel programming is wrong, or some other
| outside force is influencing my zone such as the phase of the moon or
| number of resident aliens in the local area.
| One question, though: If I cut the yellow wire for each window switch,
| should the EOL resistor be placed on the same yellow wire before the
| last switch, or on the green uncut wire just after the last switch?
|




alt.security.alarms Main Index | alt.security.alarms Thread Index | alt.security.alarms Home | Archives Home