[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: DSC Power832 wireless PC5132 problem



spud99@xxxxxxxxx wrote:
> I am working on installing a new DSC Power832 system and wireless
> receiver (PC5132-433) and am having a problem.
>
> Here is what I have done so far:
>  - I am trying to add 2 wireless transmitters (WLS925L-433).
>  - Put the ESN's in for both transmitters, assigned them to zones 9 &
> 10.
>  - Set Zone 9 & 10 type as 03.
>  - Changed the zone attribute "8" to ON for both zones to indicate
> they are wireless zones.
>  - Executed command 902 to detect new wireless zones. Waited for 1
> minute.
>  - Ran a test (command 904) and typed in zone 09. This test produces a
> squawk when the contact is opened and again when closed. Same for zone
> #10.
>
> I know I am missing something, because when I turn on the alarm,
> neither of the two wireless zones is part of the monitoring zones. It
> is as if neither is really associated with the panel.
>
> I would appreciate any help or ideas on what I am doing wrong.
> Thanks.

Go to section 203 and turn on bits 1 and 2.
js