Re: cleaner wiring solution needed



"Charles Harris" <charris@xxxxxxxxxxxxx> wrote in message
news:WdH_d.2757$lE2.2660@xxxxxxxxxxxxxxxxxxxxxxxx
>I am currently wiring up a vista 20p system and have run into a situation
> where I will have rought 8-10 wires going to 1 screw post for aux power.
> Does anyone have any recommendations on a cleaner way to wire this up so
> that the wires will not be so messy to the single post?
>
> Charles
>

You can take a single wire to the post and wire nut your 8-10 others to
it... A little cleaner than it was...

A nicer way would be to use a terminal strip with the one wire from that
post looping through to several terminals on the strip so the strip becomes
a distribution bus.

Depending on the gauge of wires involved, the cleanest I've seen employs a
66 punch down block to patch everything through.