[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]
Re: Problem With CM11A, ActiveHome 3.5 and Keyspan USB/Serial
David White <whitedavidp@xxxxxxxxxxx> wrote:
>Hello. On the 1st, I used the built-in COM port on my computer to reset
>the clock and timers on my X10 CM11A. I do this every year. I used
>version 3.5 of ActiveHome and all went well as usual.
>
>I recently purchased a Keyspan USB->Serial adapter and installed the
>latest drivers. I have used it a little and so far it seems to work
>fine. But tonite I tried it with ActiveHome. It seems to work at least
>to some extent. By this, I mean that the communications module seems to
>load/unload, that the communications test reports all is well, and that
>I can turn modules on/off.
>
>However, the set interface clock function seems to be having problems.
>It never seems to stop reading the time on the CM11A and no results are
>displayed. After checking the log from the Keyspan, I can see the
>command 0x8B is sent but it appears that the read never completes. After
>googling a bit I have seen that the 0x8B should return 16 bytes of data.
>However, I never see more than 12-14 returned.
>
>So I guess my question is: have others seen this? Any ideas/fixes? Thanks.
My guess is that X-10's programmers have set a time limit for receiving the
data. All USB-serial adapters are slower than regular RS232 because two
translations have to be made, one for each end of the USB link. You'll
probably have to use the real COM port for this task.
http://davehouston.net
http://tech.groups.yahoo.com/group/roZetta/
roZetta-subscribe@xxxxxxxxxxxxxxx