is the concern receiving an xpl message to execute an application on a
remote pc?

the sender of the message needs to know the path to the application as
well as the name of the application.  if it knows that, then the rogue
application was already put onto the machine, which is a problem
already.  if it's already there, it's most likely already going to
have it's own built in listeners on some unsecured windows port anyway.

remote exec apps are quite abundant for windows:
http://www.mkssoftware.com/docs/man1/rexec.1.asp
http://www.winrshd.com
http://www.chiark.greenend.org.uk/~sgtatham/doit
http://galaga.netlab.uky.edu/~ryang/Miscellaneous/KickOff/kickoff.htm

--- In ukha_xpl@xxxxxxx, "Paul Robinson" <ukcueman@y...>
wrote:
>
> Not sure how concerned we should be, but this does open up the
concept of xPL viruses.
> Should there at least be a list of allowed programs that can be
executed, perhaps in an
> XML config file?
>
> ----- Original Message -----
> From: "Mal Lansell" <mal@l...>
> To: <ukha_xpl@xxxxxxx>
> Sent: Wednesday, October 26, 2005 3:47 PM
> Subject: [ukha_xpl] exec.basic - comments please
>
>
> > Following up the talk of an xPLExec application for launching
> > arbitrary executables, I propose the following schema:
> >
> > xpl-cmnd
> > exec.basic
> > {
> >     pid=num       //integer identifier (<2^32)
> >     program=""    //executable filename (without path)
> >     path=""       //path to exe (optional)
> >     path=""       //as many as needed
> >     args=""       //program command line argument
(optional)
> >     args=""       //as many as needed
> > }
> >
> > xpl-stat
> > exec.basic
> > {
> >     pid=num       //same integer as sent in the xpl-cmnd
> >     status=[Failed][Started][Finished]
> >     return=""     //extended info if status is failed
or finished
> > }
> >
> > The pid is a program ID - it is not the same as the Windows
Process
> > ID, but is a user specified number to enable status messages to
be
> > associated with commands from xPLHal without having to match the
> > entire message body.  If only one program is spawned at a time,
then
> > feel free to just set it to the same value every time if you
like.
> >
> > Program is the name of the executable file to run, without any
path.
> >
> > As many or as few (none is ok) Path and Arg elements can be
included
> > as needed.
> >
> > Each Path item must contain only one piece of the path with no /
or
> > \.  These will be inserted by the receiving application.
> >
> > Each Arg item must contain only one command line argument.
> >
> > The xPLExec application will attempt to spawn the executable, and
> > will respond with a status messages containing either
status=failed
> > or status=started.  If status=failed, then the return item will
be
> > set to one of the following values:
> >
> > "argument list too long"
> > "invalid argument"
> > "program not found"
> > "program not executable"
> > "out of memory"
> >
> > If the program runs fine, the an xpl-stat message with
> > status=started will be sent.  When the spawned program
terminates,
> > another xpl-stat message will be sent, this time with
> > status=finished, and the return item set to the return value from
> > the spawned program.
> >
> > Windows spawn functions also support specifying a set of
environment
> > variables, but I couldn't see a good way of including those in
the
> > schema, with all their potential oddball characters.  Hopefully
that
> > will not be too much of a restriction.
> >
> > Comments would be appreciated.
> >
> > Mal
> >
> >
> >
> >
> >
> >
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
>
>
>
>
>
>
> ___________________________________________________________
> Yahoo! Messenger - NEW crystal clear PC to PC calling worldwide with
voicemail http://uk.messenger.yahoo.com
>







xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.