[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: Getting variable value from xPL_HomeVision from xPL script...
- Subject: Re: Getting variable value from xPL_HomeVision from
xPL script...
- From: "rleong1" <rleong1@xxxxxxxxx>
- Date: Tue, 24 May 2005 19:51:13 -0000
the osd.basic call should be this instead of what i pasted in the
previous message.
call
xpl.SendMsg("XPL-CMND","*","osd.basic","text="
& StatusText)
--- In ukha_xpl@xxxxxxx, "rleong1" <rleong1@y...> wrote:
> i don't have homevision & i'm not sure exactly what you're trying
to
> do, but let me try to take a stab at it. looking at the docs included
> with xpl_homevision, i came up w/ this:
>
> Sub GSHED_HVISION_OUTLAW_trigger(XplMsg)
> Dim CurrentValue
> Dim StatusText
> Dim MyMsg
>
> '
> ' HV status is SENSOR.BASIC schema
> '
> if
UCASE(xpl.getparam(XplMsg,"{SCHEMA}",true))="SENSOR.BASIC"
then
> '
> ' check if TYPE is PERIODIC, DEVICE is IMMERSION and CURRENT is
> OCCURRED
> '
> if
(UCASE(xpl.getparam(XplMsg,"TYPE",true))="PERIODIC")
and
>
(UCASE(xpl.getparam(XplMsg,"DEVICE",true))="IMMERSION")
and
>
(UCASE(xpl.getparam(XplMsg,"CURRENT",true))="OCCURRED")
then
> '
> ' create an xpl message to request "HVVARIABLE" from HV
> ' change this to whatever variable you want to read from HV
> '
> MyMsg = "DEVICE = HVVARIABLE" & chr(10) &
"CURRENT = REQUEST"
> call
>
xpl.SendMsg(XPL-STAT,"GSHED_HVISION.OUTLAW","CONTROL.BASIC",MyMsg)
> '
> ' this is where we process the response to the above request
> ' check if TYPE is VARIABLE and DEVICE is HVVARIABLE
> '
> elseif
(UCASE(xpl.getparam(XplMsg,"TYPE",true))="VARIABLE")
and
>
(UCASE(xpl.getparam(XplMsg,"DEVICE",true))="HVVARIABLE")
> '
> ' Extract value from CURRENT field
> '
> CurrentValue = xpl.getparam(XplMsg,"CURRENT",true)
> StatusText = "STATUS UPDATE:\nImmersion: " &
CurrentValue
> call
xpl.SendMsg("XPL-CMND","*","osd.basic","text="
& StatusText)
> end if
> End Sub
>
> watch the line wrapping in this post, it'll probably cause syntax
> errors if you do a straight copy paste. hopefully there aren't any
> other syntax errors :P
>
> --- In ukha_xpl@xxxxxxx, Andrew Kilgore <andrew.kilgore@g...>
> wrote:
> > Hi Frank,
> >
> > Not quite...
> > The conditions of the determinator is that a specific periodic
event
> fired...
> > The actions are to execute a script which will query HV for a
> specific
> > variable value send that value out in an osd.basic message...
> >
> > So far in the script I have:
> >
> > Sub GSHED_HVISION_OUTLAW_trigger(XplMsg)
> > Dim CurrentValue
> > Dim StatusText
> >
> > CurrentValue = xpl.GetParam(XplMsg, "current",
True)
> >
> > ' Display the caller details on any on-screen displays, e.g.
> Tivo
> > StatusText = "STATUS UPDATE:\nImmersion: " &
CurrentValue
> > call
xpl.SendMsg("","","osd.basic","text="
& StatusText)
> > End Sub
> >
> > However, as XplMsg refers to the periodic event trigger, that I
> > currently get is:
> > STATUS UPDATE:
> > Immersion: OCCURRED
> >
> > So, I need someway of obtaining the appropriate variable value
from
> > within the script so that I can use it to build up the text send
out
> > as the osd.basic message.
> >
> > How does "xpl.SendMsg()" work...?
> > Does it block...?
> > Does it return a confirmation message...?
> >
> > Many thanks,
> > Andy.
> >
> > On 5/22/05, Frank Mc Alinden <frankmc@i...> wrote:
> > > Hi Andy
> > > Are you saying you want the value stored in a hv
> variable to be
> > > sent out in a Determinator???
> > >
> > > Frank
> > >
> > > ----- Original Message -----
> > > From: "Andrew Kilgore" <andrew.kilgore@g...>
> > > To: "xpl" <ukha_xpl@xxxxxxx>
> > > Sent: Sunday, May 22, 2005 8:19 PM
> > > Subject: [ukha_xpl] Getting variable value from
xPL_HomeVision
> from xPL
> > > script...
> > >
> > >
> > > > Hi all,
> > > >
> > > > Need a gentle push with this one...
> > > >
> > > > Can someone point me at a simple example of how I can
get the
> value of
> > > > an HV variable within a script that gets executed as
one of my
> > > > deteminator actions?
> > > >
> > > > Many thanks,
> > > > Andy.
> > > >
> > > >
> > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > > http://www.xpl.myby.co.uk
> > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > > Yahoo! Groups Links
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > >
> > >
> > >
> > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > > To Post a Message: ukha_xpl@xxxxxxx
> > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > Yahoo! Groups Links
> > >
> > >
> > >
> > >
> > >
> > >
> > >
xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe: ukha_xpl-subscribe@xxxxxxx
To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|