Hi Frank,

Thanks for the tips - I'm certain they'll be very useful...

After all our hard work, it turns out that having HV notify me of
variable changes will not work efficiently for me. As a test I was
playing about with my immersion (momentary) switch which starts a
timer for 0.4 seconds. Everytime the timer fires I change the colour
of an LED and restart the timer. This continues until the switch is
released. This worked fine but runs like a dog with variable reporting
enabled (as the timer event sets a couple of variables)

:o(

I'll have to think of another way round this - will let you know what
I come up with...!

Thanks,
Andy.

On 5/21/05, Frank Mc Alinden <frankmc@xxxxxxx> wrote:
>  Hi Andy
>              Not sure if you are aware but if you need to create a
>  Determinator when a Particular event has occurred ie change in
variable ,
> if
>  you highlite the reported message in xPL -Mon and right click , then
select
>  create a Determinator , this will automagically create the input
condition
>  for your Determinator , you then only have to  create the Actions
section
> of
>  the Determinator...-)
>
>  Also theres another option when you right click , Populate a Global
and
> this
>  will allow you to save say the value of the variable in to an xPL
Global ,
>  it requests which section of the message to store in the Global (
current=
>  in this case) and then create the Determinator...;-)
>
>  The Determinator i wrote last nite captures a  hv periodic event 
"Vacancy
>  Counter 2" which decrements a variable once every 5 minutes if
no movement
>  or ir detected.....
>
>  I have it displaying a message saying the variable has changed and
also
> the
>  current value of the variable using the 2 Determinators mentioned
>  above..........
>
>  HTH
>  Frank
>
>
>
>  ----- Original Message -----
>  From: "fondlezz" <amkilgore@xxxxxxx>
>  To: <ukha_xpl@xxxxxxx>
>  Sent: Saturday, May 21, 2005 11:47 AM
>  Subject: [ukha_xpl] Re: xPL newbie (still!) needs help with
xPL_HomeVision
>  (detecting variable chang
>
>
>  > Eureka!
>  >
>  > I got it working just as your mail came through...
>  > I hadn't initially enabled the automatic reporting of variables
and
>  > tried earler but this seemed to have no effect. What I didn't
realise
>  > is that I needed to reload my schedule into HV for this to take
> effect...!
>  >
>  > It's now working perfectly!
>  > Thanks you so much for all your help! I think (this time) I'm
well on
>  > my way to finally integrating xPL into my setup.
>  >
>  > Now we can sleep!
>  >
>  > Many thanks,
>  > Andy.
>  > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<frankmc@i...> wrote:
>  > > Hi Andy
>  > >
>  > >           I have enabled the DDE message reporting........
>  > > Also Under controller setting , pc comms i also have
Variables ticked
> to
>  > > enable auto reporting...??
>  > >
>  > > xPL-HVISION   setting  which you access via xPL devices in
xPL
>  > Manager  , i
>  > > have  ddespeed set at 500 and lastsent at 3 and assumeok
set to
> Y.......
>  > >
>  > > HTH
>  > > Frank
>  > >
>  > >
>  > >
>  > > ----- Original Message -----
>  > > From: "fondlezz" <amkilgore@n...>
>  > > To: <ukha_xpl@xxxxxxx>
>  > > Sent: Saturday, May 21, 2005 11:28 AM
>  > > Subject: [ukha_xpl] Re: xPL newbie (still!) needs help with
>  > xPL_HomeVision
>  > > (detecting variable chang
>  > >
>  > >
>  > > > Hi Frank,
>  > > >
>  > > > Thanks - I got it off the files section...
>  > > > Still same problem though... :o(
>  > > >
>  > > > So, I'm thinking the reason that xPL_HomeVision
doesn't detect the
>  > > > change is bacuse HV isn't telling it... I'm starting
to think that
>  > > > there's something not quite right with my HV setup...
>  > > > Did you have to change anything other than enabling
DDE
>  > send/receive...?
>  > > > What version of the HV software are you running...?
>  > > >
>  > > > Thanks,
>  > > > Andy.
>  > > >
>  > > > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<frankmc@i...>
>  > wrote:
>  > > > > Hi Andy
>  > > > >             Have uploaded my version to the files
section of the
>  > list
>  > > > >
>  > > > > HTH
>  > > > > Frank
>  > > > >
>  > > > >
>  > > > > ----- Original Message -----
>  > > > > From: "Frank Mc Alinden"
<frankmc@i...>
>  > > > > To: <ukha_xpl@xxxxxxx>
>  > > > > Sent: Saturday, May 21, 2005 10:32 AM
>  > > > > Subject: Re: [ukha_xpl] Re: xPL newbie (still!)
needs help with
>  > > > > xPL_HomeVision (detecting variable chang
>  > > > >
>  > > > >
>  > > > > > Hi Andy
>  > > > > >
>  > > > > >         Got the following error when i sent
you the
>  > xPL-HVISION file
>  > > > > >
>  > > > > > This Message was undeliverable due to the
following reason:
>  > > > > >
>  > > > > > Your message is larger than the destination
computer is willing
> to
>  > > > > > accept, so it was returned.  The error
message below indicates
> the
>  > > > > > size of your message and the maximum size
allowed by the
> receiving
>  > > > > > E-mail system.  You may be able to split
your message into
> several
>  > > > > > smaller pieces and have them delivered
separately.
>  > > > > >
>  > > > > > Your message was rejected by
gmail-smtp-in.l.google.com for the
>  > > > following
>  > > > > > reason:
>  > > > > >
>  > > > > >      5.7.0 Illegal Attachment
>  > > > > >
>  > > > > > The following recipients did not receive
this message:
>  > > > > >
>  > > > > >      <andrew.kilgore@g...>
>  > > > > >
>  > > > > > Please reply to <Postmaster@m...>
>  > > > > > if you feel this message to be in error.
>  > > > > >
>  > > > > > The original message has been removed from
the bounce message
>  > > > > >
>  > > > > >
>  > > > > >
>  > > > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
>  > > > > http://www.xpl.myby.co.uk
>  > > > > > To Post a Message: ukha_xpl@xxxxxxx
>  > > > > > To Subscribe:
> ukha_xpl-subscribe@xxxxxxx
>  > > > > > To Unsubscribe:
> ukha_xpl-unsubscribe@xxxxxxx
>  > > > > > Yahoo! Groups Links
>  > > > > >
>  > > > > >
>  > > > > >
>  > > > > >
>  > > > > >
>  > > > > >
>  > > >
>  > > >
>  > > >
>  > > >
>  > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
>  > > http://www.xpl.myby.co.uk
>  > > > To Post a Message: ukha_xpl@xxxxxxx
>  > > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
>  > > > To Unsubscribe:
> ukha_xpl-unsubscribe@xxxxxxx
>  > > > Yahoo! Groups Links
>  > > >
>  > > >
>  > > >
>  > > >
>  > > >
>  > > >
>  >
>  >
>  >
>  >
>  > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
>  http://www.xpl.myby.co.uk
>  > To Post a Message: ukha_xpl@xxxxxxx
>  > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
>  > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
>  > Yahoo! Groups Links
>  >
>  >
>  >
>  >
>  >
>  >
>
>
>
>
>  xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
>  To Post a Message: ukha_xpl@xxxxxxx
>  To Subscribe:  ukha_xpl-subscribe@xxxxxxx
>  To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
>
>
>  ________________________________
>  Yahoo! Groups Links
>
>
> To visit your group on the web, go to:
> http://groups.yahoo.com/group/ukha_xpl/
>
> To unsubscribe from this group, send an email to:
> ukha_xpl-unsubscribe@xxxxxxx
>
> Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.


xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe:  ukha_xpl-subscribe@xxxxxxx
To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx

xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.