Re: SlimP3 - XPL = Homeseer 2


  • Subject: Re: SlimP3 - XPL = Homeseer 2
  • From: "JohnQuirk" <johnquirk@xxxxxxxxx>
  • Date: Fri, 26 Aug 2005 19:34:40 -0000

Tremendous stuff Tom. I've changed Homeseer to run as a service as
local system, changed XPL HAL to run as a service as local system
too. I also changed the configuration rights (probably not required)
within DCOM config. Somehow it now works.

Thanks very much indeed.

John
--- In ukha_xpl@xxxxxxx, Tom Van den Panhuyzen <tomvdp@g...>
wrote:
> Maybe the user running the xplhal service (localsystem ?) doesn't
have the
> permission to launch the dcom server "HomeSeer.Application"
?
> Goto "Start/Run...", type "dcomcnfg". In the
management console,
navigate to
> My Computer/DCOM Config. Locate the HomeSeer Class. Check the
properties,
> especially under Security the Launch and Access Permissions. If
these are
> set to Use Default, then click look at the properties of My
Computer in the
> treeview of the management console (i.e. not the My Computer on
the
> desktop).
>  But first examine the eventlog. If it is related to what I
describe here
> you should find entries there.
>  Hth,
> Tom
>
>  On 8/26/05, JohnQuirk <johnquirk@y...> wrote:
> >
> > Hi John,
> > Good to hear from you again. I can confirm that the script works
> > fine outside of XPL, which is what I'm finding so frustrating.
> >
> > Any advice on debugging.
> >
> > Thanks
> >
> > JohnQ
> >
> >
> > --- In ukha_xpl@xxxxxxx, "John B"
<home-automation@j...>
> > wrote:
> > > Hi John,
> > >
> > > As Tony says, this looks like a problem creating the HS
object.
> > > CreateObject should work fine from within xPLHal - I use it
to
do
> > stuff
> > > with databases using ADO.
> > >
> > > Can you try putting the following lines into a file in
Notepad:
> > >
> > > Set hs = CreateObject("HomeSeer.Application")
> > > hs.Writelog "XPL","M2"
> > > hs.ExecX10 "M2", "on", 0, 0
> > > Set hs = Nothing
> > >
> > >
> > > Then save it as a VBS file and try running it.
> > >
> > > If it fails with the same error (Object variable or with
block
> > variable
> > > not set) then you know it's an error within HS.
> > > If it works, then we need to look at why it doesn't work
from
> > within
> > > xPLHal.
> > >
> > > HTH,
> > >
> > > John
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> >
> >
> >  ------------------------------
> > YAHOO! GROUPS LINKS
> >
> >
> >    - Visit your
group "ukha_xpl<http://groups.yahoo.com/group/ukha_xpl>"
> >    on the web.
> >     - To unsubscribe from this group, send an email to:
> >    ukha_xpl-unsubscribe@xxxxxxx<ukha_xpl-
unsubscribe@xxxxxxx?subject=Unsubscribe>
> >     - Your use of Yahoo! Groups is subject to the Yahoo! Terms
of
> >    Service <http://docs.yahoo.com/info/terms/>.
> >
> >
> >  ------------------------------
> >
>
>
> [Non-text portions of this message have been removed]





xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.