Hi Neil

> What simple new things can I do to learn the power of xPL. I currently
use
> MH for my normal HA.

Since you have x10 i suppose start there.......Dont really use x10 myself
so
cant give any samples.....


> How do I get the devcomm app and install it. Where does the "OSD
schema"
fit
> in and "CONTROL.BASIC schema"

You get the devcom from Tonys site ...go to vb6 apps .....

http://www.xplhal.com/

The OSD schema is for display devices such as slimp3 , tivo , vfdosd , mvp,
my tvosd and my lcdosd and any other device which can display info...the
schema info can be found at the main xPL site....The control.basic schema
info can be found there too..
http://www.xplproject.org.uk/

> Where are you writing you PC code.

No pc type code to write otherwise i would be stumped.....Determinators to
the rescue ;-)

You write Determinators which watch for events and then take what ever
action is required...

For instance  if i  press the menu up button on the lcdosd ,it sends a
control basic message which has a menu number embedded within the
message....
I have a determinator which watches for the control.basic message from my
lcdosd and stores the menu number in a global (variable)....

Other Determinators watch for the buttons 1 to 4 and also check the global
for a specific number
and will send an osd message to the lcdosd if both are true...

So menu 1 button 1 could be turn on bedroom lites....The determinator will
send a cbus command to xPL-CGATE and also send an osd message to the lcd to
say the lite has been commanded ON display this for 2 seconds and then
refresh by sending menu 1 again...

Hope this makes some sense

Frank











----- Original Message -----
From: "Neil Wrightson" <neilw@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Saturday, April 23, 2005 5:33 PM
Subject: RE: [ukha_xpl] xPL-LCD Update


>
> Hi Frank,
>
> I'm new to all of this (xPL). I have the HAL,  Manager and X10
installed.
> The X10 works.
> What simple new things can I do to learn the power of xPL. I currently
use
> MH for my normal HA.
>
> How do I get the devcomm app and install it. Where does the "OSD
schema"
fit
> in and "CONTROL.BASIC schema"
>
> Where are you writing you PC code.
>
> Regards,
>
> Neil Wrightson.
> -----Original Message-----
> From: Frank Mc Alinden [mailto:fmcalind@xxxxxxx]
> Sent: Saturday, 23 April 2005 1:37 PM
> To: ukha_xpl@xxxxxxx
> Subject: Re: [ukha_xpl] xPL-LCD Update
>
>
>
> Hi Neil
>             The xPL-LCD uses Tonys devcom app which is used for serial
> devices....Im using the OSD schema to talk to the LCD .......and also
use
> the CONTROL.BASIC schema for reporting the status of the
> buttons..........The lcd talks native xPL....
>
> HTH
> Frank
>
> ----- Original Message -----
> From: "Neil Wrightson" <neilw@xxxxxxx>
> To: <ukha_xpl@xxxxxxx>
> Sent: Saturday, April 23, 2005 1:08 PM
> Subject: RE: [ukha_xpl] xPL-LCD Update
>
>
> >
> > Hi Frank,
> >
> > What code are you using at the PC end to drive your LCD?
> >
> > What is the RS232 message format used to connect to the LCD?
> >
> >
> > Regards,
> >
> > Neil Wrightson.
> > -----Original Message-----
> > From: Frank Mc Alinden [mailto:fmcalind@xxxxxxx]
> > Sent: Monday, 14 March 2005 10:51 PM
> > To: ukha_xpl@xxxxxxx
> > Subject: [ukha_xpl] xPL-LCD Update
> >
> >
> >
> > Hi Guys
> >             Been doing some work om y xPL-LCD over the weekend
and its
> > taking shape....Have got it talking to xPL ....and im able to
configure
it
> > etc....Have just made it the default OSD device for my Exstreamer
and
> > xPLRIONET is sending osd messages to it ;-)).......
> >
> > Im also displaying the time in the top line  right hand side and
have a
> > recurring event running every minute to update the time..........
> > xPLRIO was clearing the time whenever a new song started so i
have a
> > Determinator watching
> > for an OSD message from xPLRIO and i pause for 1/2 second (allow
the pic
> to
> > display the osd message) and then update the time ;-))
> >
> > Im now thinking as Mal suggested in having the Menus sent to the
lcdosd
> > (using Determinators)and track the menus using  a
global......thats the
> > theory....if it works the menus are unlimited ........
> > and all i need to do is send a trig message for each
button.....the
value
> of
> > the global and the button value will determine which Determinator
> > runs........
> >
> > More Soon
> > Frank
> > www.armaghelectrical.com.au
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk <http://www.xplproject.org.uk>
<
> http://www.xplproject.org.uk <http://www.xplproject.org.uk>
>
> > http://www.xplhal.com <http://www.xplhal.com>  < http://www.xplhal.com
> <http://www.xplhal.com>
>  http://www.xpl.myby.co.uk
> <http://www.xpl.myby.co.uk>
> > < http://www.xpl.myby.co.uk <http://www.xpl.myby.co.uk> >
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> >
> >
> >
> > Yahoo! Groups Sponsor
> >
> > ADVERTISEMENT
> >
> <
http://us.ard.yahoo.com/SIG=129jegp78/M=298184.6018725.7038619.3001176/D=g
>
<http://us.ard.yahoo.com/SIG=129jegp78/M=298184.6018725.7038619.3001176/D=g>
> >
> roups/S=1705701025:HM/EXP=1110887398/A=2593423/R=0/SIG=11el9gslf/*
> http://www <http://www>
> > .netflix.com/Default?mqso=60190075> click here
> >
> <
http://us.adserver.yahoo.com/l?M=298184.6018725.7038619.3001176/D=groups/
>
<http://us.adserver.yahoo.com/l?M=298184.6018725.7038619.3001176/D=groups/>
> > S=:HM/A=2593423/rand=484113441>
> >
> >
> >   _____
> >
> > Yahoo! Groups Links
> >
> >
> > * To visit your group on the web, go to:
> > http://groups.yahoo.com/group/ukha_xpl/
> <http://groups.yahoo.com/group/ukha_xpl/>
> > < http://groups.yahoo.com/group/ukha_xpl/
> <http://groups.yahoo.com/group/ukha_xpl/>
>
> >
> >
> > * To unsubscribe from this group, send an email to:
> > ukha_xpl-unsubscribe@xxxxxxx
> > <mailto:ukha_xpl-unsubscribe@xxxxxxx?subject=Unsubscribe>
> >
> >
> > * Your use of Yahoo! Groups is subject to the Yahoo! Terms of
Service
> > < http://docs.yahoo.com/info/terms/
<http://docs.yahoo.com/info/terms/>
>
> .
> >
> >
> >
> >
> > [Non-text portions of this message have been removed]
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk <http://www.xplproject.org.uk>
> http://www.xplhal.com <http://www.xplhal.com>
> http://www.xpl.myby.co.uk
<http://www.xpl.myby.co.uk>
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
> >
>
>
>
> xPL Links: http://www.xplproject.org.uk <http://www.xplproject.org.uk>
> http://www.xplhal.com <http://www.xplhal.com>  http://www.xpl.myby.co.uk
> <http://www.xpl.myby.co.uk>
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
>
>
>
>   _____
>
> Yahoo! Groups Links
>
>
> * To visit your group on the web, go to:
> http://groups.yahoo.com/group/ukha_xpl/
> <http://groups.yahoo.com/group/ukha_xpl/>
>
>
> * To unsubscribe from this group, send an email to:
> ukha_xpl-unsubscribe@xxxxxxx
> <mailto:ukha_xpl-unsubscribe@xxxxxxx?subject=Unsubscribe>
>
>
> * Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service
> <http://docs.yahoo.com/info/terms/>
.
>
>
>
>
> [Non-text portions of this message have been removed]
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
>



xPL Links: http://www.xplproject.org.uk http://www.xplhal.com http://www.xpl.myby.co.uk
To Post a Message: ukha_xpl@xxxxxxx
To Subscribe:  ukha_xpl-subscribe@xxxxxxx
To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx

xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.