[Message Prev][Message
Next][Thread Prev][Thread Next][Message
Index][Thread Index]
Re: Re: Trouble getting flags set in HV - I found it!!
> Exactly right!
Ok the first thing to do is create globals and give them names ie
hv_lounge...hv_bedroom1 etc
Then create Determinators which will look for input conditions from your
xpl-hvision variables...
You must delete the variables from the hvInput Exclude file that you want
reporting on..would suggest close xplhvision and then restart after you
edit
the hvinputExclude file...
In the actions part of the determinator you need to select action type =
set
the value of a global
in the global name insert the global you wish to store ....ie hv_bedroom1
in the value part you need to insert {XPL::CURRENT}
This will store the hv variable into an xpl global
HTH
Frank
----- Original Message -----
From: "gmotichka" <gmotichka@xxxxxxx>
To: <ukha_xpl@xxxxxxx>
Sent: Saturday, December 11, 2004 7:56 AM
Subject: [ukha_xpl] Re: Trouble getting flags set in HV - I found it!!
>
>
> Exactly right!
>
>
>
>
> --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<fmcalind@b...>
> wrote:
> > Hi George
> >
> > > Yes it is now working.
> >
> > Great news !!
> >
> > > Frank, Do you have any globals working. I am thinkging that
is
> what
> > > I would use to monitor temps from HV. Is that correct?
> >
> > Yes George i have im using globals to store temp values from the
> xpltom10
> > app......I assume you having temp values in hv variables is that
> correct and
> > want to get them into xpl globals ???
> >
> > Frank
> >
> >
> >
> >
> > ----- Original Message -----
> > From: "gmotichka" <gmotichka@h...>
> > To: <ukha_xpl@xxxxxxx>
> > Sent: Saturday, December 11, 2004 7:50 AM
> > Subject: [ukha_xpl] Re: Trouble getting flags set in HV - I found
> it!!
> >
> >
> > >
> > >
> > > Yes it is now working.
> > >
> > > It looks like I was using a template determinator that was
built
> > > before mal updated the w800.
> > >
> > > After he did that I reinstalled the service with a slighly
> different
> > > name, but the template was still looking for the first name.
> Once I
> > > repicked the source to be equal to the new name, it worked
as it
> > > should.
> > >
> > > Frank, Do you have any globals working. I am thinkging that
is
> what
> > > I would use to monitor temps from HV. Is that correct?
> > >
> > > George
> > >
> > >
> > >
> > > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
> <fmcalind@b...>
> > > wrote:
> > > > Hi George
> > > > Are you saying you have it working now
???
> > > >
> > > > Frank
> > > >
> > > >
> > > > ----- Original Message -----
> > > > From: "gmotichka" <gmotichka@h...>
> > > > To: <ukha_xpl@xxxxxxx>
> > > > Sent: Saturday, December 11, 2004 7:43 AM
> > > > Subject: [ukha_xpl] Re: Trouble getting flags set in HV
- I
> found
> > > it!!
> > > >
> > > >
> > > > >
> > > > >
> > > > > When I re installed the w800 service after mal
incorporated
> the
> > > > > delay,I know have two instances of a sourec in the
dropdown
> box.
> > > > > The one I had picked was not the correct one. Once
I picked
> the
> > > > > correct one it acted as expected.
> > > > >
> > > > > So how do I get rid of the non active instance in
the drop
> down
> > > box?
> > > > >
> > > > > George
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > > --- In ukha_xpl@xxxxxxx, "gmotichka"
<gmotichka@h...>
> > > wrote:
> > > > > >
> > > > > > Yes, Absolutely sure it is enabled.
> > > > > >
> > > > > > Frank
> > > > > > I've also tried both combinatins of case -
all caps, first
> > > cap,
> > > > > no
> > > > > > caps.
> > > > > >
> > > > > > I appreciate you guys scratching your heads
on this. Do you
> > > think
> > > > > it
> > > > > > couls have anything to do with the delay mal
put into the
> w800?
> > > > > >
> > > > > > George
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > >
> > > > > > --- In ukha_xpl@xxxxxxx, "John B"
<home-
> > > automation@j...>
> > > > > > wrote:
> > > > > > > Hi George,
> > > > > > >
> > > > > > > > When I was relaying what was on the
condition screen,
> I was
> > > > > > typing
> > > > > > > > it in so yes it was a misprint.
Here is exactly what
> ther
> > > is
> > > > > as
> > > > > > > > pasted from the boxes:
> > > > > > >
> > > > > > > I think Frank may have mentioned this
before, but have
> you
> > > made
> > > > > > sure the "This determinator is
enabled" check box is
> ticked?
> > > > > > >
> > > > > > > The "Execute Now" menu item
will always work, even if a
> > > > > > determinator is not enabled, however it will
only act upon
> it's
> > > > > > input conditions if it is enabled.
> > > > > > >
> > > > > > > Regards,
> > > > > > >
> > > > > > > John
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > > > http://www.xpl.myby.co.uk
> > > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > > > Yahoo! Groups Links
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > >
> > >
> > >
> > >
> > >
> > >
> > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > http://www.xpl.myby.co.uk
> > > To Post a Message: ukha_xpl@xxxxxxx
> > > To Subscribe: ukha_xpl-subscribe@xxxxxxx
> > > To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> > > Yahoo! Groups Links
> > >
> > >
> > >
> > >
> > >
> > >
> > >
>
>
>
>
>
>
> xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
http://www.xpl.myby.co.uk
> To Post a Message: ukha_xpl@xxxxxxx
> To Subscribe: ukha_xpl-subscribe@xxxxxxx
> To Unsubscribe: ukha_xpl-unsubscribe@xxxxxxx
> Yahoo! Groups Links
>
>
>
>
>
>
>
>
xPL Main Index |
xPL Thread Index |
xPL Home |
Archives Home
|