The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024

Latest message you have seen: Re: vendor ID reservation


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Trouble getting flags set in HV


  • Subject: Re: Trouble getting flags set in HV
  • From: "gmotichka" <gmotichka@xxxxxxxxxxxxx>
  • Date: Fri, 10 Dec 2004 20:02:22 -0000



Tried that before, but just re tried again. STill no go.

George





--- In ukha_xpl@xxxxxxx, "Frank Mc Alinden" <fmcalind@b...>
wrote:
> Hi George
>
> > Target              GSHED-HVISION.HOMEVISION
>
> If you look in the reply from w800 app you will see target=*...so
you need
> to use * ......try that please.......
>
> HTH
> Frank
>
>
>
> ----- Original Message -----
> From: "gmotichka" <gmotichka@h...>
> To: <ukha_xpl@xxxxxxx>
> Sent: Saturday, December 11, 2004 6:54 AM
> Subject: [ukha_xpl] Re: Trouble getting flags set in HV
>
>
> >
> >
> > I cant see where it is different. Here is what is in my
Condition of
> > my determinator:
> >
> > Condition Type      xPL Message
> > Message Type        Trigger
> > Source              mal-w800rf32
> > Target              GSHED-HVISION.HOMEVISION
> > Scheme              x10.basic
> >
> > Message             command=on
> > Parameters          device=A4
> >
> > George
> >
> >
> >
> >
> >
> > --- In ukha_xpl@xxxxxxx, "Frank Mc Alinden"
<fmcalind@b...>
> > wrote:
> > > Sorry
> > > > I would say your input condition ISNT matching exactly
as
per the
> > > receieved
> > > > w800 message ,as it looks like your actions part is
> > correct.......
> > > Frank
> > >
> > > ----- Original Message -----
> > > From: "Frank Mc Alinden" <fmcalind@b...>
> > > To: <ukha_xpl@xxxxxxx>
> > > Sent: Saturday, December 11, 2004 6:32 AM
> > > Subject: Re: [ukha_xpl] Trouble getting flags set in HV
> > >
> > >
> > > >
> > > > Hi George
> > > >
> > > > Firstly is the Determinator enabled ???
> > > >
> > > > I would say your input condition is matching exactly as
per
the
> > receieved
> > > > w800 message ,as it looks like your actions part is
> > correct.......
> > > >
> > > >
> > > > > The other wierd thing is that even thought the
above is
taken
> > from
> > > > > the TX window, the deteminator "Action"
shows the source
being
> > blank
> > > > > and the target being
"GSHED-HVISION.HOMEVISION"
> > > >
> > > > Thats correct the message is a confirmation from xpl
hvisio
that
> > it has
> > > > executed a xpl command...
> > > > That part is ok .....
> > > >
> > > > Frank
> > > >
> > > >
> > > > ----- Original Message -----
> > > > From: "gmotichka" <gmotichka@h...>
> > > > To: <ukha_xpl@xxxxxxx>
> > > > Sent: Saturday, December 11, 2004 6:24 AM
> > > > Subject: [ukha_xpl] Trouble getting flags set in HV
> > > >
> > > >
> > > > >
> > > > >
> > > > >
> > > > > Well I tried everything I can think of and without
success
I
> > am back
> > > > > to ask some questions.
> > > > >
> > > > > I have xPL and Homevision working great on x10
commands to
fire
> > > > > macros or send lighting commands.
> > > > >
> > > > > I am now trying to set flags in HV from a message
from x10
IR
> > > > > detectors.
> > > > >
> > > > > The info comes fromt the w800 fine. I see this in
the
> > xPLHomevision
> > > > > Rx screen:
> > > > >
> > > > > xpl-trig
> > > > > {
> > > > > hop=1
> > > > > source=mal-w800rf32.xplw800com6
> > > > > target=*
> > > > > }
> > > > > x10.basic
> > > > > {
> > > > > command=on
> > > > > device=A4
> > > > > }
> > > > >
> > > > > But nothing happens on the Tx side - no commands
are going
to
> > HV
> > > > > when this arrives
> > > > >
> > > > > BUT when I do an "Execute Now" on the
same determinator I
get
> > this
> > > > > in the HV Tx window and the flag does indeed get
set:
> > > > >
> > > > > xpl-trig
> > > > > {
> > > > > hop=1
> > > > > source=gshed-hvision.homevision
> > > > > target=*
> > > > > }
> > > > > control.confirm
> > > > > {
> > > > > device=31
> > > > > type=FLAG
> > > > > current=SET
> > > > > name=Office Occupency
> > > > > }
> > > > > The other wierd thing is that even thought the
above is
taken
> > from
> > > > > the TX window, the deteminator "Action"
shows the source
being
> > blank
> > > > > and the target being
"GSHED-HVISION.HOMEVISION"
> > > > >
> > > > > Thanks
> > > > > George
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > > xPL Links: http://www.xplproject.org.uk
http://www.xplhal.com
> > > > http://www.xpl.myby.co.uk
> > > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > > > > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > > > > Yahoo! Groups Links
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > > >
> > > >
> > > >
> > > >
> > > >
> > > > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> > > http://www.xpl.myby.co.uk
> > > > To Post a Message: ukha_xpl@xxxxxxx
> > > > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > > > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > > > Yahoo! Groups Links
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> >
> >
> >
> >
> >
> >
> > xPL Links: http://www.xplproject.org.uk http://www.xplhal.com
> http://www.xpl.myby.co.uk
> > To Post a Message: ukha_xpl@xxxxxxx
> > To Subscribe:  ukha_xpl-subscribe@xxxxxxx
> > To Unsubscribe:  ukha_xpl-unsubscribe@xxxxxxx
> > Yahoo! Groups Links
> >
> >
> >
> >
> >
> >
> >
> >






xPL Main Index | xPL Thread Index | xPL Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.