Re: Re: xAP control of X10 Extended commands via Homeseer


  • Subject: Re: Re: xAP control of X10 Extended commands via Homeseer
  • From: James Traynor <james@xxxxxxx>
  • Date: Tue, 08 May 2007 21:06:00 +0100
  • References: <f1p84o+o7aq@xxxxxxxxxxx>

--------------090408020004010406000207
Content-Type: text/plain; charset=ISO-8859-1; format=flowed
Content-Transfer-Encoding: 7bit

Jon wrote:
>
> James,
>
> Thank you. Your updated ocx seems to be working perfectly with
> extended dim commands with Edwards X10 connector. I've tried it both
> via an event and directly, both so far without issues.
>
Excellent
>
> As I have it configured, I'm using the X10 connector as the X10
> target. I assume in this mode that I cannot trigger on X10 received.
> Is there a way to 'tell' Homeseer that an X10 command has been
> sent/received and it's value?
>
Yes, can be done. In teh xAPx10 connector go to file>properties and go
to the xAP tab.  Turn on xAPx10 schema send.  Now x10 messages are sent
over xAP and the homeseer plugin should receive them.
>
> Regarding the first page load issue, I would not worry about it.
> 99.99% of people do not do what I was doing. I've corrected the
> problem by using the Homeseer uptime to prevent any script running
> under 60 seconds on my Home page. This obviously stops them running on
> start-up. If you wish to see how I push Homeseer to the limit, you can
> go to www.jon00.me.uk/hs.html <http://www.jon00.me.uk/hs.html>
>
It's quite a site, I remember seeing it when i first used HS and
thinking how!
>
> Another question, I've been happily running a Wireless AP for years
> without issues. Over the last few days it keeps crashing which
> co-incidentally is the same time as I've been playing with xAP. I'm
> wondering if the two are related?
>
I have seen an old netgear AP throw a wobble when it receives too many
broadcasts, an update to it's latest firmware fixed it.

btw, we have a weekly chat at www.mi4.biz/talk  each Tuesday at 9pm feel
free to pop by!


James

--------------090408020004010406000207
Content-Type: text/html; charset=ISO-8859-1
Content-Transfer-Encoding: 7bit

<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01
Transitional//EN">
<html>
<head>
<meta content="text/html;charset=ISO-8859-1"
http-equiv="Content-Type">
<title></title>
</head>
<body bgcolor="#ffffff" text="#000000">


Jon wrote:
<blockquote cite="mid:f1p84o+o7aq@xxxxxxx"
type="cite">
<p>James,</p>
<p>Thank you. Your updated ocx seems to be working perfectly with
extended dim commands with Edwards X10 connector. I've tried it both
via an event and directly, both so far without issues.</p>
</blockquote>
Excellent<br>
<blockquote cite="mid:f1p84o+o7aq@xxxxxxx"
type="cite">
<p>As I have it configured, I'm using the X10 connector as the X10
target. I assume in this mode that I cannot trigger on X10 received. Is
there a way to 'tell' Homeseer that an X10 command has been
sent/received and it's value?</p>
</blockquote>
Yes, can be done. In teh xAPx10 connector go to file&gt;properties and
go to the xAP tab.&nbsp; Turn on xAPx10 schema send.&nbsp; Now x10
messages are
sent over xAP and the homeseer plugin should receive them.<br>
<blockquote cite="mid:f1p84o+o7aq@xxxxxxx"
type="cite">
<p>Regarding the first page load issue, I would not worry about it.
99.99% of people do not do what I was doing. I've corrected the problem
by using the Homeseer uptime to prevent any script running under 60
seconds&nbsp;on my Home page. This obviously stops them running on
start-up.
If you wish to see how I push Homeseer to the limit, you can go to <a
moz-do-not-send="true" href="http://www.jon00.me.uk/hs.html";>www.jon00.me.uk/hs.html</a></p>
</blockquote>
It's quite a site, I remember seeing it when i first used HS and
thinking how!<br>
<blockquote cite="mid:f1p84o+o7aq@xxxxxxx"
type="cite">
<p>Another question,&nbsp;I've been happily running a Wireless AP
for&nbsp;years without issues. Over the last few days it keeps crashing
which co-incidentally is the same time as I've been playing with xAP.
I'm wondering if the two are related?</p>
</blockquote>
I have seen an old netgear AP throw a wobble when it receives too many
broadcasts, an update to it's latest firmware fixed it.<br>
<br>
btw, we have a weekly chat at <a
class="moz-txt-link-abbreviated" href="http://www.mi4.biz/talk";>www.mi4.biz/talk</a>&nbsp;
each Tuesday at 9pm
feel free to pop by!<br>
<br>
<br>
James<br>

<span width="1" style="color:
white;"/>__._,_.___</span>


<!-- **begin egp html banner** -->

<img src="http://geo.yahoo.com/serv?s=97476590/grpId=9674343/grpspId=1705007709/msgId=3637/stime=1178654801";
width="1" height="1"> <br>

<!-- **end egp html banner** -->


<!-- **begin egp html banner** -->

<br><br>
<div style="width:500px; text-align:right; margin-bottom:1px;
color:#909090;">
<tt>SPONSORED LINKS</tt>
</div>
<table bgcolor=#e0ecee cellspacing="13"
cellpadding="0" width=500px>
<tr valign=top>
<td style="width:25%;">
<tt><a href="http://groups.yahoo.com/gads;_ylc=X3oDMTJjMWlibGx1BF9TAzk3NDc2NTkwBF9wAzEEZ3JwSWQDOTY3NDM0MwRncnBzcElkAzE3MDUwMDc3MDkEc2VjA3NsbW9kBHN0aW1lAzExNzg2NTQ4MDE-?t=ms&k=X10+home+automation&w1=X10+home+automation&w2=Home+automation&w3=Home+automation+product&w4=Home+automation+system&w5=Home+automation+security&c=5&s=133&g=0&.sig=tN49yZ8gLW44qGV8ngn-6Q";>X10
home automation</a></tt>
</td>
<td style="width:25%;">
<tt><a href="http://groups.yahoo.com/gads;_ylc=X3oDMTJjczdjYWJyBF9TAzk3NDc2NTkwBF9wAzIEZ3JwSWQDOTY3NDM0MwRncnBzcElkAzE3MDUwMDc3MDkEc2VjA3NsbW9kBHN0aW1lAzExNzg2NTQ4MDE-?t=ms&k=Home+automation&w1=X10+home+automation&w2=Home+automation&w3=Home+automation+product&w4=Home+automation+system&w5=Home+automation+security&c=5&s=133&g=0&.sig=uxodCh5B-C-LfzJs4AF_uw";>Home
automation</a></tt>
</td>
<td style="width:25%;">
<tt><a href="http://groups.yahoo.com/gads;_ylc=X3oDMTJjNjZsOHRvBF9TAzk3NDc2NTkwBF9wAzMEZ3JwSWQDOTY3NDM0MwRncnBzcElkAzE3MDUwMDc3MDkEc2VjA3NsbW9kBHN0aW1lAzExNzg2NTQ4MDE-?t=ms&k=Home+automation+product&w1=X10+home+automation&w2=Home+automation&w3=Home+automation+product&w4=Home+automation+system&w5=Home+automation+security&c=5&s=133&g=0&.sig=-7-yoKCdmzYOn0eQU41W8Q";>Home
automation product</a></tt>
</td>
</tr>
<tr valign=top>
<td style="width:25%;">
<tt><a href="http://groups.yahoo.com/gads;_ylc=X3oDMTJjcjdzOXFiBF9TAzk3NDc2NTkwBF9wAzQEZ3JwSWQDOTY3NDM0MwRncnBzcElkAzE3MDUwMDc3MDkEc2VjA3NsbW9kBHN0aW1lAzExNzg2NTQ4MDE-?t=ms&k=Home+automation+system&w1=X10+home+automation&w2=Home+automation&w3=Home+automation+product&w4=Home+automation+system&w5=Home+automation+security&c=5&s=133&g=0&.sig=YiCpy6REMq-ZQ9BflM6GVg";>Home
automation system</a></tt>
</td>
<td style="width:25%;">
<tt><a href="http://groups.yahoo.com/gads;_ylc=X3oDMTJjbGRoOHVkBF9TAzk3NDc2NTkwBF9wAzUEZ3JwSWQDOTY3NDM0MwRncnBzcElkAzE3MDUwMDc3MDkEc2VjA3NsbW9kBHN0aW1lAzExNzg2NTQ4MDE-?t=ms&k=Home+automation+security&w1=X10+home+automation&w2=Home+automation&w3=Home+automation+product&w4=Home+automation+system&w5=Home+automation+security&c=5&s=133&g=0&.sig=MqsbZg2eMmjgfWfWU0yLgQ";>Home
automation security</a></tt>
</td>
</tr>
</table>

<!-- **end egp html banner** -->


<!-- **begin egp html banner** -->

<br>
<div style="font-family: verdana; font-size: 77%; border-top: 1px
solid #666; padding: 5px 0;" >
Your email settings: Individual EmailTraditional <br>
<a href="http://groups.yahoo.com/group/xap_automation/join;_ylc=X3oDMTJma3V1NnVxBF9TAzk3NDc2NTkwBGdycElkAzk2NzQzNDMEZ3Jwc3BJZAMxNzA1MDA3NzA5BHNlYwNmdHIEc2xrA3N0bmdzBHN0aW1lAzExNzg2NTQ4MDE-";>Change
settings via the Web</a> (Yahoo! ID required) <br>
Change settings via email: <a href="mailto:xap_automation-digest@xxxxxxx?subject=Email
Delivery: Digest">Switch delivery to Daily Digest</a>  <a
href = "mailto:xap_automation-fullfeatured@xxxxxxx?subject=Change
Delivery Format: Fully Featured">Switch to Fully Featured</a>
<br>
<a href="http://groups.yahoo.com/group/xap_automation;_ylc=X3oDMTJkc3M0M2JvBF9TAzk3NDc2NTkwBGdycElkAzk2NzQzNDMEZ3Jwc3BJZAMxNzA1MDA3NzA5BHNlYwNmdHIEc2xrA2hwZgRzdGltZQMxMTc4NjU0ODAx";>
Visit Your Group
</a>
<a href="http://docs.yahoo.com/info/terms/";>
Yahoo! Groups Terms of Use
</a>
<a href="mailto:xap_automation-unsubscribe@xxxxxxx?subject=Unsubscribe";>
Unsubscribe
</a>
<br>
</div>
<br>

<!-- **end egp html banner** -->


<span  style="color: white;"/>__,_._,___</span>
</body>
</html>

--------------090408020004010406000207--

xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.