The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Re: xap-comfort


  • Subject: Re: Re: xap-comfort
  • From: Max Barker
  • Date: Mon, 12 Apr 2004 20:49:00 +0000

<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0
Transitional//EN">
<DIV><FONT face="Arial" size="2">Running on
XP home. I'm able to log in using hyperterminal.</FONT></DIV>
<DIV><FONT face="Arial" size="2">This is
what I'm putting&nbsp;I'm at the command prompt</FONT><FONT
face="Arial" size="2"></FONT></DIV>
<DIV><FONT face="Arial"
size="2"><EM></EM></FONT>&nbsp;</DIV>
<DIV><FONT face="Arial"
size="2"><EM>xap-comfort [****]
[com2]</EM></FONT></DIV>
<DIV><FONT face="Arial"
size="2"><EM></EM></FONT>&nbsp;</DIV>
<DIV><FONT face="Arial" size="2">where
<EM>[****]</EM> is a valid sign in
code</FONT></DIV>
<DIV><FONT face="Arial"
size="2"></FONT>&nbsp;</DIV><FONT
face="Arial" size="2">
<DIV><EM>Comfort Interface for xAP v12Copyright (C) Patrick
Lidstone, 2002eth0: address 192.168.1.13eth0: netmask
255.255.255.0Autoconfig: xAP broadcasts on 192.168.1.255:3639xAP
uid=FF000600, source=Rocket.Comfort.HomeBroadcast socket port 3639 in
use</EM></DIV>
<DIV><EM>Assuming a hub is activeSocket port 3639 in useSocket
port 3640 in useSocket port 3641 in useSocket port 3642 in useSocket port
3643 in useSocket port 3644 in useSocket port 3645 in useSocket port 3646
in useSocket port 3647 in useSocket port 3648 in useSocket port 3649 in
useSocket port 3650 in useSocket port 3651 in useDiscovered port 3652Using
serial port <[com2]>Unable to open serial port</EM></DIV>
<DIV>&nbsp;</DIV>
<DIV>&nbsp;</DIV>
<DIV>xap-comfort then starts sending out heartbeats and processing
xap messages (all say something like "no target in header, not for
us).</DIV>
<DIV>&nbsp;</DIV>
<DIV>&nbsp;</DIV>
<DIV>If I input </DIV>
<DIV>&nbsp;</DIV>
<DIV><EM>xap-comfort **** com2</EM></DIV>
<DIV>&nbsp;</DIV>
<DIV>at the command prompt,&nbsp; I get the same message except
the end</DIV>
<DIV>&nbsp;</DIV>
<DIV><EM>Using serial port <com2></EM></DIV>
<DIV>&nbsp;</DIV>
<DIV>and no further action from the app. No heartbeats. In fact, I
can't even close the window.</DIV>
<DIV>&nbsp;</DIV>
<DIV>Max</DIV>
<DIV>&nbsp;</DIV>
<DIV>&nbsp;</DIV>
<DIV></FONT>----- Original Message ----- </DIV>
<BLOCKQUOTE>
<DIV><B>From:</B> <A title="patrick@xxxxxxx"
href="mailto:patrick@xxxxxxx";>patrick@xxxxxxx</A>
</DIV>
<DIV><B>To:</B> <A
title="xap_automation@xxxxxxx" href="mailto:xap_automation@xxxxxxx";>xap_automation@xxxxxxx</A>
</DIV>
<DIV><B>Sent:</B> Monday, April 12, 2004 6:54
PM</DIV>
<DIV><B>Subject:</B> [xap_automation] Re:
xap-comfort</DIV>
<DIV><FONT face="Arial"
size="2"></FONT><FONT face="Arial"
size="2"></FONT><FONT face="Arial"
size="2"></FONT><FONT face="Arial"
size="2"></FONT><FONT face="Arial"
size="2"></FONT></DIV><TT>--- In <A
href="mailto:xap_automation@xxxxxxx";>xap_automation@xxxxxxx</A>,
"Max Barker" <<A href="mailto:max@v";>max@v</A>...>
wrote:> I've just setup xap comfort and I'm getting an "unable to
open serial port" message. The port in question is com2, a virtual
serial port connected to a lantronix mss100. Any idea what I can try
next?> What platform are you running on?Assuming windows, are you able
to open com2 using hyperterminal or equivalent?Patrick</TT>




xAP_Automation Main Index | xAP_Automation Thread Index | xAP_Automation Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.