The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Re: cbus Wiser appears to be in UK stockist



AIUI a PCI or a CNI , including that within the Wiser can't be used by
more than one device or application at a time, nor can multiple IP
connections be actually created to a standard CNI.   This is really
because the various users of the interface can set the interface into
different modes, plus there is a message
tagging/sequencing/acknowledgement algorithm that could get ambiguous
with multiple users.

I'm guessing that once you use Toolkit the Wiser will relinquish use
of the inbuilt CNI and hence iPhone control would cease.   Certainly
that other iPhone C-Bus control app behaved this way and I know that my
gateway can't connect via Wiser and still maintain Wiser
functionality.    So really the inbuilt CNI is pretty much dedicated
either to Wiser or another (usually Toolkit) use.   So you're not really
gaining a spare CNI.

K


On 19/01/2010 15:26, ben_mccormack2000 wrote:
> One think I am unsure of. If I use the iphone control can I also at
the same time use cbus toolkit to make changes. I think I have read that
Wiser can support 6 different ip connections at a time
>
> I wonder what my CNI is worth!
>
> Ben



------------------------------------

<*> Join the Automated Home Forums
http://www.automatedhome.co.uk/vbulletin/


UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.