RE: Silent Gliss Autoglide


  • Subject: RE: Silent Gliss Autoglide
  • From: "ben addison" <ben@xxxxxxxxxxxxxx>
  • Date: Fri, 13 Mar 2009 08:18:00 -0000

Andrew,



You would need to connect the curtain supply to a fused spur. I would
always
supply the spur from the ring main, but if you can only get to the lighting
circuit then it will be fine for the odd curtain.

If your doing the whole house I would put all the curtains on there only
circuit, or run each one back to node 0 and install a 24v supply.



Ben



_____

From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf Of
Andrew Walker
Sent: 12 March 2009 07:51
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] Silent Gliss Autoglide



Ok, thanks for that.

So the motor electronics must be permanently wired/plugged into the
mains? Would a fused spur be required? Could it come off the lighting
circuit?

-----Original Message-----
From: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
[mailto:ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com] On Behalf
Of Neil Fuller
Sent: 11 March 2009 20:24
To: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
Subject: Re: [ukha_d] Silent Gliss Autoglide

Andrew

The 5090 just needs a momentary closure of the switch to initiate an
"open" or "close".

As Ben said, you remove the switch and connect it to a CBUS relay (the
CBUS relays are volt free).

Set cbus up so that the relay closes for a short period via a Timer
action(1 second is more than enough) to initiate an "open" or
"close" of
the curtains. Set the Timer delay up in the Blocks tab

Currently, mine operate from one of the buttons on the Saturn switches
but will operate via light level when I get around to it!

HTH

Neil

Andrew Walker wrote:
>
> Hi Ben,
>
> I am thinking of adding some curtain control in the near future, could

> you explain how it is achieved with a simple cbus relay. I thought I
> would need one of the new cbus blind and shutter control relays?
>
> cheers
>
> -----Original Message-----
> From: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>
> [mailto:ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>]
On
> Behalf Of ben addison
> Sent: 10 March 2009 22:48
> To: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>
> Subject: RE: [ukha_d] Silent Gliss Autoglide
>
> Hi Rob,
>
> The RACUB should be fine to control the 5090, I use the 5090 on most
> jobs and control them from a c-bus relay or comfort.
>
> The RACUB looks to be a zero volt relay.
>
> All you need to do is just cut the switch off that comes with the 5090

> then connect the green and yellow wire across the N/O relay.
>
> I do sell Silent Gliss products if you would like me to quote for
> anything.
> Most items can be delivered to you the same week.
>
> Thanks
>
> Ben Addison
>
> _____
>
> From: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>
> [mailto:ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>]
On
> Behalf Of Rob James
> Sent: 10 March 2009 22:25
> To: ukha_d@yahoogroups. <mailto:ukha_d%40yahoogroups.com>
com
<mailto:ukha_d%40yahoogroups.com>
> Subject: [ukha_d] Silent Gliss Autoglide
>
> I've been looking at the Silent Gliss Autoglide 5090 system but I have

> a few questions that hopefully someone can answer.
>
> I have Rako controlled lighting in use in the room I would like to use

> these curtains motors, but I'm not sure whether the 5090 basic model
> will be compatible with the RACUB.
>
> If it is compatible, and if I wasn't worried about independant curtain

> control, could more than one 5090 be used with a single RACUB?
>
> Can anyone recommend a competitive supplier?
>
> Regards
>
> Rob
>
> __________________________________________________________
> Free photo editing software from Windows Live . Try it now!
> http://clk.atdmt.
<http://clk.atdmt.
<http://clk.atdmt.com/UKM/go/134665240/direct/01/>
com/UKM/go/134665240/direct/01/
> <http://clk.atdmt.
<http://clk.atdmt.com/UKM/go/134665240/direct/01/>
com/UKM/go/134665240/direct/01/>>
> com/UKM/go/134665240/direct/01/
>
> [Non-text portions of this message have been removed]
>
> Internal Virus Database is out of date.
> Checked by AVG - www.avg.com
> Version: 8.0.233 / Virus Database: 270.10.18/1935 - Release Date:
> 02/04/09 16:35:00
>
> [Non-text portions of this message have been removed]
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>

------------------------------------


UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.