Re: Need to switch immersion heater on/off possibly with relay?


  • Subject: Re: Need to switch immersion heater on/off possibly with relay?
  • From: "Lehane Kellett" <lehane@xxxxxxxxxxxxxxxxxxx>
  • Date: Sat, 18 Apr 2009 08:03:35 -0000

I use a 25A SSR (Solid State Relay) which is silent. Since they are
used in=
industrial plant you can get them in many sizes. 3kW is about 13A, so a 25=
A one has plenty of headroom. The control voltage varies by model but is
us=
ually a wide spec - I control the SSR from an xAP Netiom at 12V. Don't
forg=
et to independently protect the AC supply.

New from RS they're about =A320 but I see on *bay there are some at =A36
ea=
ch....

Lehane




--- In ukha_d@xxxxxxx, "Gary" <questuk1@...> wrote:
>
> Hi
>=20
> I would like to control my 3kw Immersion Heater, but not sure what to
use=
?
>=20
> X10 modules I don't think are powerful enough?
>=20
> Relay, wouldn't this just arc and weld itself together after a few
tries?
>=20
> Triac's get very hot at this load?
>=20
> Any ideas very welcome, ideally would like to buy a ready made pcb or
mod=
ule, cost is an issue.
>=20
> Thanks all
>=20
>=20
> Regards=20
>=20
> Gary
>




------------------------------------


UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home