RE: [OT] Networking Problem



Last time I saw this it was a network cable that had had the pairs
split
wrongly ... check for miswirings on either plugs or punchdowns.

If you have this problem then after testing with a cheap cabletester
they'll
still measure through perfectly but simply won't transfer at 100mbits.

Phil



> -----Original Message-----
> From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
> Of Chris Miles
> Sent: 20 November 2007 23:10
> To: ukha_d@xxxxxxx
> Subject: Re: [ukha_d] [OT] Networking Problem
>
> Just one switch. Everything is set to 100mb full duplex.
>
> If it was that it wouldnt explain why
>
> machine 1 to machine 2 - 100mb
> machine 2 to machine 1 - 100mb
> machine 2 to NAS - 100mb
>
> it is just machine 1 to NAS which is slow.
>
> Doesnt add up.
>
> thanks
>
> Chris
>   ----- Original Message -----
>   From: Nigel Giddings
>   To: ukha_d@xxxxxxx
>   Sent: Saturday, November 17, 2007 3:22 PM
>   Subject: RE: [ukha_d] [OT] Networking Problem
>
>
>   Are you only using one switch?
>
>   You may have an issue with auto negotiation, ideally you want
100Mbit
>   Full Duplex
>
>   HTH
>
>   Nigel
>
>   -----Original Message-----
>   From: Chris Miles [mailto:chrismiles@xxxxxxx]
>   Sent: 17 November 2007 14:42
>   To: ukha_d@xxxxxxx
>   Subject: [ukha_d] [OT] Networking Problem
>
>   I have a strange problem where I cant get fast speeds transferring
> files
>   from one my my hard wired machines to one of my NAS boxes. Only
seems
> to
>   be about 10mbps.
>
>   I can transfer from this machine to another machine at 100mbps.
>   I can transfer from the second machine to the NAS box at 100mbps.
>
>   So there cant be a problem with the wiring between the first
machine,
>   second machine, or NAS box.
>
>   What else could it be??
>
>   Chris
>
>   [Non-text portions of this message have been removed]
>
>   [Non-text portions of this message have been removed]
>
>
>
>
>
>
>
-----------------------------------------------------------------------
> -------
>
>
>   Internal Virus Database is out-of-date.
>   Checked by AVG Free Edition.
>   Version: 7.5.446 / Virus Database: 268.18.12/724 - Release Date:
> 16/03/2007 12:12
>
>
> [Non-text portions of this message have been removed]
>
>
>
>
>
>




UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.