Stuart,

So far I've found that it responds to the following undocumented commands
(that are documented for
eg the LC2D series :-

Colour temperature (ku)
Red, Green and Blue adjust (kv, kw & k$)
LowPowerMode (jq) - not sure if this does anything
OrbiterTime (jr) - likewise
OrbiterPixel (js) - ditto
PIP enable (kn) Off = 0, PIP = 1, DW1 = 2, DW2 = 3, POP (programme scan) =
4

There's no PIP positioning command that I've found so far, but that's
probably because the LX2R
series lets you position and size the PIP pretty much anywhere on screen
rather than in fixed positions.

I've also found that the Tint control seems to be the only one that doesn't
support sending FF as
the data to retrieve the current setting, but that may be because the set
has to be in the
appropriate input mode e.g. TV and tuned to a channel (I have no aerial
connected to my set so I
haven't really played with the tuner yet).

Stuart Poulton wrote:
>
>
> Rob,
>
> I'd be interested in what un-documented features you've found ?
>
> Thanks
>
> Stuart
>
> On Thu, 2006-11-02 at 09:21 +0000, Rob Heyes wrote:
>  > David wrote:
>  > >
>  > >
>  > > Does anyone know of any brands of LCD TV that supports
RS232 Control
>  > >
>  >
>  > Lots of LG TVs support RS232 e.g.
>  >
>  > 23LZ25, 23LZ55, 26LC2R, 26LX2R, 26LX1R, 26LZ55,26LZ5RV,
>  > 27LZ5RV, 27LC2R, RZ-30LZ13, 32LC2D, 32LC2DB, 32LC2R
>  > 32LC3R, 32LX1R, 32LX2R, 32LZ55, 37LC2D, 37LC2DB, 37LZ31
>  > 42LC2D, 42LC2DB, 42LZ31
>  >
>  > Similarly for a lot of their plasma displays as well. The
protocol varies
>  > a bit between models, and some of the functions aren't
documented
> (e.g. I've found
>  > about 5 undocumented functions on my 32LX2R). One thing to be
aware
> of however is that
>  > (at least on the nnLX2R series) you don't get any feedback from
the
> set when it is operated by the
>  > remote, and you also cannot query the set for the current input
> selection :(
>  >
>  > Also note that as far as I know these are model numbers as
available
> in the EU - you may have
>  > different models in NZ - worth checking out the manuals on the
LGE
> support website -
>  > http://www.lge.com/support/manual.jsp
> <http://www.lge.com/support/manual.jsp>
>  >
>
>




** Sponsored by http://www.BERBLE.com **
all the Cool Stuff, in one Place



UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.