RE: Air Con - WAS: RE: Fw: It's that time of year again...


  • Subject: RE: Air Con - WAS: RE: Fw: It's that time of year again...
  • From: "Hawes,Timothy Edward \(GEG\)" <haweste@xxxxxxxxxxxxxxx>
  • Date: Tue, 21 Jun 2005 11:43:53 +0100

This exact question came up recently on the UK_Selfbuild list. FWIW, I
think it's a really *bad* idea, and you still may need planning/listed
building consent if you do still go ahead. You should check with the
planning office to be sure.
Anyway, here's the UK_Selfbuild Q&A.

HTH,

Tim.

66
Question:
> I'm contemplating installing an air conditioner in our bedroom, the
> question is - is there any reson why the 'outdoor' part of the system
> cannot be installed in the loft? The loft is well ventilated and well
> insulated from the rest of the house.

Answer:
'Well ventilated' is not the same as having free air flow.
The outdoor unit will be putting out at least 2kW (for a 1.5kW indoor).
That'll heat up the attic considerably.  The hotter the attic gets, the
less cooling the indoor unit can do.  Then there's a maximum temperature
the outdoor unit can work at.  Also, the hotter the outdoor unit
environment, the shorter its life.
99


> -----Original Message-----
> From: aashram
>
> Can I do this
>
> I have top floor flat. Above me is a huge empty pitched loft.
> I am separated from the loft by a concrete layer. I have
> access to this loft no problem.
> It is just dead space which spans the whole floor.
>
> Can I put the outdoor unit in the loft above ? what is the
> maximum distance I can have the outdoor unit as my ceilings are 13ft.
>
> This would be a life saver if I could do this as I would need
> planning permission.
>
> -----Original Message-----
> From: Jim Noble
>
> aashram wrote:
>
> > Would love to have this but I live in a grade II listed
> building and I
> > don't think they will allow me to have this system sticking out
the
> > wall. Unless there is another option ?
>
>
> Put the "outdoor" unit in the loft, beef up the top floor
> ceiling insulation, and ventilate the loft well?
>
> Jim