The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

RE: AirCon - with no digital buttons !??


  • Subject: RE: AirCon - with no digital buttons !??
  • From: "John Andrews" <groups@xxxxxxxxxxxxxxxx>
  • Date: Tue, 12 Jul 2005 18:05:51 +0100

Chris

As I am about to move house (have air con fitted here) can I ask, what
did you use to self install?

Cheers

-----Original Message-----
From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
Of christopher purves
Sent: 12 July 2005 17:06
To: ukha_d@xxxxxxx
Subject: RE: [ukha_d] AirCon - with no digital buttons !??


Hmmm you have just reminded me I forgot to fit aircon to my node zero
having
just fitted 8 other units around the house. Damn!

Chris

>From: "Neil Ball" <neilball@xxxxxxx>
>Reply-To: ukha_d@xxxxxxx
>To: <ukha_d@xxxxxxx>
>Subject: RE: [ukha_d] AirCon - with no digital buttons !??
>Date: Tue, 12 Jul 2005 16:55:08 +0100
>
>Ahh, I see the problem!! Does your unit allow a remote room sensor to
>be fitted? If so you could leave the unit on and in cooling mode and
>wire in a resistor directly rather than the thermistor sensor.
>Switching between 2 fixed resistances will force the unit to run when
>needed as it will think the room temp is either way above or way below
>setpoint - it's not too difficult to find out the thermistor types used

>by the different manufacturers, but you can only do this if the unit
>supports a remote room sensor in the first place.
>
>
>
>   _____
>
>From: ukha_d@xxxxxxx [mailto:ukha_d@xxxxxxx] On Behalf
>Of Gareth Cook
>Sent: 12 July 2005 16:45
>To: ukha_d@xxxxxxx
>Subject: Fw: [ukha_d] AirCon - with no digital buttons !??
>
>
>
>I did have a HomeBase unit that has buttons and a digital display -
>only problem was when you turn it on it reset to 24 degrees and no a/c.
>
>If you know of a digital one that defaults to a/c and lowest
>temperature then it's not a problem.
>
>And yes I never intended to hack the a/c unit - just an x10 appliance
>module for example.
>
>G.
>
>   _____
>
>
>
>[Non-text portions of this message have been removed]
>
>
>
>
>Yahoo! Groups Links
>
>
>
>
>
>






UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.