Re: NetGear DG834G



Stuart Grimshaw wrote:
> On Sat, 22 May 2004 21:09:42 +1200, Richard Malcolm-Smith
> <rich@xxxxxxx> wrote:
>
>>Thats the nat table filling up.
>>
>>The 253 users come from it only supporting a /24 subnet internally.
2
>>totally
>>different issues.
>
>
> Any way to stop/ fix it?

Get a cisco or something industrial strength.

The problem with p2p applications is they send a lot of syns that never get
an
answer, and for some reason the routers dont time these out really quickly.
It
would make sense that if the remote host didnt respond in a few seconds
that it
never would.

I recall a dlink "broadband router" I looked at had room for a
huge 127 entries
in the nat table, but at least it failed gracefully and just closed older
connections rather then crashing.