The UK Home Automation Archive

Archive Home
Group Home
Search Archive


Advanced Search

The UKHA-ARCHIVE IS CEASING OPERATIONS 31 DEC 2024


[Message Prev][Message Next][Thread Prev][Thread Next][Message Index][Thread Index]

Re: Extend volume control for active speakers and Kiosk earthing.


  • Subject: Re: Extend volume control for active speakers and Kiosk earthing.
  • From: "ianh1000" <ianh1000@xxxxxxxxx>
  • Date: Sat, 14 Aug 2004 14:14:54 -0000

Hi Keith

I guess my question about an earth on the PC was that it will be
connected to other devices that could introduce mains voltage due to
a fault. Ethernet, Telephone, the active speakers. I am happy that
the PC has no mains present in normal operation, just wondering if it
was a good precaution really.

Thanks for the advice on the 10k in line log pot, I will give that a
try.

Many Thanks
Ian

--- In ukha_d@xxxxxxx, "Keith Doxey" <ukha@d...> wrote:
> Hi Ian,
>
> As you are using the ITX PSU there is no mains connectd to the
Kiosk
> PC so it doesnt need an earth.
>
> Regarding the volume control, leave it exactly where it is but
turned
> up full.
>
> Simply buy a 10K LOG pot and fit it in the lead that you will be
> running to the Kiosk PC. It will do exactly the same job.
>
> KIOSK PC  POT            Active Speakers
> Signal----
>          \
>          /
>          \<------------  signal
>          /
>          \
>          /
> Ground------------------ ground
>
> Obviously the other channel will also be done the same.
>
> Hope that helps
>
> Keith
>
>
>
> --- In ukha_d@xxxxxxx, "ianh1000" <ianh1000@y...>
wrote:
> > Hi All, I hope someone can help.
> >
> > I have bough some small active speakers to use with the kisok PC
in
> > the kitchen. They have a volume control on the rear and will be
> > mouted on top of the cabinets out of reach. I want to move the
> volume
> > control about 1.5m away so that it is placed beside the PC.
> >
> > I have the skills to take the dual pot off the PCB and extend it
> with
> > some wire to a new location but I am not sure if this is ok to do
> or
> > not. Obviosuly there is some additional resistance in the extra
> wire
> > but they are 50k pots so nothing that should cause too much of an
> > issue if I use a reasonable gauge wire.
> >
> > Any reason I should not do this? Should I ensure that the remote
> pot
> > and Kiosk PC case are properly earthed? I am using a silent ITX
PSU
> > so the Kiosk chassis currently has no earth connection and I will
> > have it installed in the kitchen, I assume it makes sense to
> connect
> > the casing to a good earth.
> >
> > Thanks in advance.
> >
> > Ian




UKHA_D Main Index | UKHA_D Thread Index | UKHA_D Home | Archives Home

Comments to the Webmaster are always welcomed, please use this contact form . Note that as this site is a mailing list archive, the Webmaster has no control over the contents of the messages. Comments about message content should be directed to the relevant mailing list.